Product description
- Overhead sectional door/sectional door with panels of extruded, E6-EV1, anodized, high strength insulated aluminium profiles as supporting frame (Height 450 - 600 mm).
- Life time expectations door: 200000 door cycles or 10 years, when service/replacement program has been performed.
- Infills optionally double glazing. One or two panes, depending on the daylight width of the door
- Integrated finger pinch protection
- Top, bottom and side seals and seals between door sections
- Standard track system in galvanized steel
- Spring balancing, 20000 cycles
- Spring break device
- Lock bolt, step-handle,
- Compliance with all operational and safety instructions in EU Directives and the standards of the European Standardization Committee (CEN)
- Standard hardware (head room 485/510 mm to 800 mm)
- Operating system: manual
- Standard door sizes (DLW x DLH) MIN: 2.050 x 2.150 mm MAX: 5.500 x 4.250 mm
- Resistance to wind load
EN 12424 Insulated panel sections Class 3 (DLW ≤ 4250)
Class 2 (4250 < DLW) (Higher classes on request)
Framed sections Class 3 (DLW ≤ 3650)
Class 2 (3650 < DLW) (Higher classes on request)
- Thermal transmittance (EN 12428) 2.0W/(m2∙K) double glazing DE4D
- Water penetration (EN 12425) Class 3 (Door 4.000 x 4.000 mm)
- Air permeability (EN 12426) Class 3 (Door 4.000 x 4.000 mm)
Glazing
- Option: DH4D, double glazing 2 x 4 mm hardened glass; Thermal transmittance glazing, 2,75W/(m2∙K)
- Option: DH6D, double glazing 2 x 6 mm hardened glass; Thermal transmittance glazing, 2,75W/(m2∙K)
- Option: DE4D, double glazing 2 x 4 mm hardened glass with Argon filling; Thermal transmittance glazing, 1,1W/(m2∙K)
- Option: DE6D, double glazing 2 x 6 mm hardened glass with Argon filling; Thermal transmittance glazing, 1,1W/(m2∙K)
Bottom Sections
- Standard: Insulated aluminium frame construction
- Option: Sandwich panel across entire width; Section height 545 mm plus bottom seal
(other glazing / sandwich unit designs available on request)
Options
Surface color
□ Insulated aluminium frame
- Standard: E6/EV1 anodized
- Option: interior and / or exterior painted in standard colors
- Option: interior and / or exterior painted in RAL-standard color buyer’s choice
- Option: interior and / or exterior painted according to color sample
- Option: interior and exterior powder coated
□ Sandwich panel
- Standard: Aluminium panel aluminium interior and exterior or
- Standard: Steel panel interior RAL 9002, exterior standard colors
- Option: Aluminium and steel panel interior and/or exterior painted according to color sample
- Option: Aluminium and steel panel interior and / or exterior painted in RAL-standard colors buyer’s choice
Door locking device
- Option: Lock with profile cylinder lockable on one or both sides
- Option: Door locking switch (essential with electric operation)
Hardware
- LL drop clearance, 265 mm (≤250 kg), 300 mm (>250 kg)
- HL drop clearance, HL+320 mm (HL ≤3321 mm), HL+370 mm (HL >3321 mm)
- HHL drop clearance, HL+220 mm (HL ≤3321 mm), HL+270 mm (HL >3321 mm)
- VL drop clearance min. door height + 400 mm
Operator
- Option: Chain hoist “T” (Gear ratio 1:4, Door weight max. 250 kg)
- Option: Chain hoist “U” (Gear ratio 1:3, Door weight over 250 kg)
- Option: Electronic operator:
- Operating voltage: 230 V AC, 50/60 HZ (internal supply 3-phase 230 V AC)
- Operating factor: ED = 30%, S3 10 min, non-continuous operation
- (Engine operation 3 min, pause 7 min, direct-inverting)
- Torque: 15-40 Nm, depending on reel type (value of given door shaft)
- Fusing: 10 A
- Brake: non-reversible worm gear
- Speed monitor: electronic monitoring
- Freewheel / clutch: mechanical engagement/disengagement
- Limit switch: electronic via torque (setting “Door open” during programming) Setting “Door closed” in processor board
- Gears: worm gear 1750 RPM yields approx. 24 rotations door shaft
- Shaft: ø35 mm or hexagonal
- Direct drive system
- No special wall reinforcement necessary
- Temperature range: -20°C to 60°C
- Soft stop, soft start
- Connection using “CEE plug” or lockable mains isolator
- Maximum door weight 400 kg
Options
- Chain transmission
- Chain guard
Other drive variants available on request subject to technical inspection
Control units
Control unit 950
Output 0.37 kW, input 1 x 230 V. Dimensions: 180 × 380 × 120 mm (wxhxd) including control unit with standard actuator UP-STOP-DOWN and pulse control incl. self-monitoring safety edge. Counter/error code display and servicing info display in top of control cabinet. Operating speed 0.25 m/s, safety rating IP 55. If there is a power failure, the disengage device enables manual operation at any time.
Options
- Radio remote control
- “Open” (if open button is used during closing process - door immediately stops and opens completely)
- “Automatic close” (safety photo cell compulsory requirement) Door closes automatically after set period (2-932 sec)
- Pull switch for OPEN / CLOSE
- External push-button, key switch
- “One-button function” - opens or closes door, depending on actual status (e.g. radio, pull switch)
- additional safety (e.g. photo cell, radar) – door immediately opens completely
- Photo cell
- Reduced opening height
- Radar
- Magnetic loop
- Warning lights
- Traffic lights
- Interlocking door function
- Door/bridge interlock
- Connectivity to enable monitoring and accessing door data via ASSA ABLOY Insight. For more information see: https://www.assaabloyentrance.....
Selection of automation options
- Red lights, included, flashing/steady continuously when door is moving/between end limits
- Red flashing/steady light before “Automatic close”.
- Steady red light with door closed available.
- Start time for flashing/steady lights before closure can be set.
- Magnetic loop, included, with various functions, e.g.
- “Safety and acknowledge signal”.
- “Open and acknowledge signal”.
- “Safety and open”.
- “Open”.
- Via a DIP-switch setting safety may also work as acknowledge signal.
- Interlocking door function or mutual interlocking between two doors
- Incl. 24 V AC max. 400 mA for additional units.
- Relays with optional settings, typically and default “Door open” or “Door closed”.
- Combination of ‘Red lights’ and ‘Magnetic loop’
- Red lights (included) flashing/steady continuously when door is moving.
- Red flashing/steady light (included) before “Automatic close”.
- Steady red light with door closed available.
- Start time for flashing/steady lights before closure can be set.
- Magnetic loop (included) with various functions, e.g.
- “Safety and acknowledge signal”.
- “Open and acknowledge signal”.
- “Safety and open”.
- “Open”.
- Via a DIP-switch setting safety may also work as acknowledge signal.
Note! Position indications use the two available outputs, combinations are possible but limited, expansions/combinations on request.
- Directional sensor traffic light (including red/green)
- Control of oncoming traffic in the doorway.
- Using “Open inside” or “Open outside” to control oncoming traffic.
- Oncoming traffic sees alternately red or green light, depending on which “Open command” is given first.
Other supplementary equipment
□ Anti-corrosive hardware
- Anti-corrosive package Type “C”
- Stainless steel hinges and roller brackets
- Stainless steel screws
- Stainless steel roller shafts and door cables
- Aluminium top and bottom profile
- Powder coated corner bracket (RAL 9002)
- Anti- corrosive package Type “A”
- Stainless steel hinges and roller brackets
- Stainless steel screws
- Stainless steel roller shaft and door cables
- Aluminium top and bottom profile
- Powder coated corner bracket (RAL 9002)
- Powder coated end caps, trusses, tracks, hangers, connection beams, buffers, safety pull sets (RAL 9002)
- Anti- corrosive package Type “S”
- Safety pull cables, stainless steel
- Anti- corrosive package Type “Z”
- Electro-galvanized springs (max. 70.000 cycles)
□ Collision protection
- Track protection kit
- Reinforced bottom profile
□ Cable break device
□ Increased cycle spring (20.000 – 100.000)
Special models
Fixed top and side sections, with and without passdoor, in the same color and construction as the door leaf are available on request! (subject to technical inspection)