Publikovat produkty
Wilkins 700XL Dual Check Valve, 1/2" - 3/4"
Wilkins

Wilkins 700XL Dual Check Valve, 1/2" - 3/4"

Ideal for use where Lead-Free* valves are required. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. The Model 700XL shall provide protection where a potential health hazard does not exist.

Compliance
• ASSE® Listed 1024
• CSA® Certified B64.6
• Meets the requirements of NSF/ANSI 61 and 372*
*(0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)

Features:

  • Several configuration options ease installation and repairs
  • Horizontal or vertical installation reduces installation time and associated costs
  • Comes standard with a union inlet connection and integral body outlet connection
  • Quality stainless steel springs and low-lead bronze body resist corrosion
  • ASSE® Listed 1024
  • CSA® Certified
  • Meets the requirements of NSF/ANSI 61
  • Lead-Free


Specifikace
  • The Dual Check Valve Backflow Preventer shall be certified to NSF/ANSI 61, and ASSE® Listed 1024. The main body shall be low lead cast bronze (ASTM B 584), the check assemblies shall be NORYL ® (1/4”-1/2”) or DELRIN® (3/4”-1”). The seal ring and o-rings shall be Buna Nitrile. The Dual Check Valve shall be a ZURN WILKINS Model 700XL.

    keywords: Automotive Center,Retail,Manufacturing Floor,Industrial,Office Space,Drip Irrigation,Residential/Commercial Irrigation,Classrooms,School Systems,Educational Facilities,Universities,Custodial Closets,Military,Janitorial Closets,Sports Complex/Recreational Center,Residential Multi-Family,Residential/Light Commercial,On-Site Office,Correctional/Institutional,Janitorial Closets/Custodial Closets,Architectural/Aesthetics,Storage Areas,Development,Civil,Maintenance Facilities/Storage,Transportation,Food Service,Industrial/Processing Plant,Boiler Rooms and Custodial Areas,Healthcare,Hospitality,Government Buildings,High Rise Buildings,Backflow Preventers,Lead-Free Products,Zurn Wilkins Water Control,Power Generation,Residential Single-Family,Waterworks,Single and Dual Checks,Zurn Wilkins Backflow Preventers,Z-Bite™ Solderless Connections,Z-Press™ Solderless Connections,Lead-Free Law Compliance,MasterSpec,Retrofit and Replacement,Water Conservation,Zurn Wilkins,,00XL,0XL

Technická specifikace
  • Jedinečná ref. hodnotazurn-700xl
  • Skupina výrobkůBackflow Preventers
  • Skupina produktůSingle & Dual Check
  • TypObjekt
  • Datum zveřejnění2025-09-02
  • Číslo vydání1
Související
  • Hlavní materiálBronze
  • Navrženo vSpojené státy americké
Klasifikace
  • Kategorie BIMobjectInstalace - Ventily

Dostupnost regionu

Severní Amerika
Anguilla
Antigua a Barbuda
Aruba
Bahamy
Barbados
Belize
Bermudské ostrovy
Britské Panenské ostrovy
Curaçao
Dominika
Dominikánská republika
Gaudeloupe
Grenada
Grónsko
Guatemala
Haiti
Honduras
Jamajka
Kajmanské ostrovy
Kanada
Karibské Nizozemsko
Kostarika
Kuba
Martinik
Mexiko
Montserrat
Nikaragua
ostrovy Turks a Caicos
Panama
Pannenske Ostrovy
Portoriko
Saint-Pierre a Miquelon
Salvador
Spojené státy americké
Svatá Lucie
Svatý Bartoloměj
Svatý Kryštof a Nevis
Svatý Martin
Svatý Martin
Svatý Vincenc a Grenadiny
Trinidad a Tobago
Knihovna produktů BIMobject

Design App pro Revit

Načtěte rodiny přímo do svého modelu Revit jedním kliknutím

Získejte místo pro snadnější přístup k novým objektům, ukládejte své rodiny Revit a spolupracujte se svým týmem.

  • ZaškrtnutíPracujte přímo s objekty BIM vedle Revitu
  • Zaškrtnutí 2 GB cloudové úložiště – ukládejte svůj obsah Revitu
  • Zaškrtnutí Získejte posouzení životního cyklu (A1–A3) uhlíku zabudovaného přímo z Revitu