Two Stage Infrared Heater, Model TXR

Two Stage Infrared Heater, Model TXR

Model TXR - As the Model TX with extra features for harsh and outdoor environments. Model TXR includes a potted module, sealed burner housing, and heat-treated aluminized. Stainless steel available.

  • Two stage heater – Approved for outdoor use
  • 40,000 to 220,000 BTU/h
  • Natural Gas or LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated controls compartment – electronics out of air stream, burner can run during servicing
  • Self diagnostic ignition module
  • Parabolic aluminum reflectors - Most efficient in industry
  • Direct spark ignition
  • Vented or unvented
  • Jet Stream burner – improved heat distribution, better combustion
  • Heavy duty couplings – no leaks, cannot be over tightened
  • Operating status lights
  • Low voltage controls
  • TXR features burner box sealed for outdoor conditions
  • Rubber gaskets are used instead of fiber
  • Silicone used to seal corners and joints
  • Weather resistant electrical components used for exterior connections
  • Stainless steel burner boxes available as well as tubing and reflectors
  • Units are wind resistant
  • Three year warranty on all components
  • Five year warranty on hot rolled heat exchanger
  • Seven year warranty on aluminized heat exchanger
  • 10 year warranty on aluminized heat exchanger with post purge feature
Specifikation
  • Low-Intensity Two Stage Infrared Tube Heaters. Heavy-duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents within the range of 40/30 MBH to 220/165 MBH with a minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. The product shall be (please select model for unique specification) Model TA (sealed blower design), Model TX (enclosed burner design), or Model TXR (enclosed, moisture sealed burner design for rugged, harsh environments or outdoor use) as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks shall be possible with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors shall have a minimum of 10 reflective surfaces.  Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing, and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution most include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model. 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Teknisk specifikation
  • Unik ref.txr
  • ProduktfamilieTwo Stage Infrared Heaters
  • ProduktgruppeLow Intensity - Series T
  • TypeObjekt (enkelt objekt)
  • Udgivelsesdato2021-02-16
  • Udgavenummer1
Relateret
  • Materiale primærtStål
  • Materiale sekundærtAluminium
  • Designet iCanada
  • Fremstillet iCanada
Klassifikation
  • BIMobject-kategoriHVAC - Varmeapparater
  • UNSPSC-navnTubular heaters
  • UNSPSC-kode40101822
  • Uniclass 2015-kodePr_70_60_36_72
  • Uniclass 2015-beskrivelseRadiant tube heaters
  • CSI MasterFormat 2014-kode23 55 23
  • CSI MasterFormat 2014-titelGas-Fired Radiant Heaters
  • OmniClass-nummer23-33 15 17 13
  • OmniClass-betegnelseFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II-kodeD30
  • CSI UniFormat II-titelHVAC

Tilgængelighed i region

Europa Nordamerika Asien
Åland
Anguilla
Armenien
Albanien
Antigua og Barbuda
Aserbajdsjan
Andorra
Aruba
Bangladesh
Belgien
Bahamas
Bhutan
Bosnien-Herzegovina
Barbados
Brunei Darussalam
Bulgarien
Belize
Cambodia
Cypern
Bermuda
Cocosøerne
Danmark
Canada
Det britiske territorium i Det Indiske Ocean
Estland
Caribbean Netherlands
Filippinerne
Færøerne
Caymanøerne
Georgien
Finland
Costa Rica
Hong Kong
Frankrig
Cuba
Indien
Gibraltar
Curaçao
Indonesien
Grækenland
De britiske jomfruøer
Japan
Guernsey
Dominica
Juleøerne
Holland
Dominikanske Republik
Kazakhstan
Hviderusland
El Salvador
Kina
Irland
Grenada
Kyrgyzstan
Island
Grønland
Laos
Isle of Man
Guadeloupe
Macau
Italien
Guatemala
Malaysia
Jan Mayen
Haiti
Maldiverne
Jersey
Honduras
Mongoliet
Kroatien
Jamaica
Myanmar (Burma)
Letland
Jomfruøerne
Nepal
Liechtenstein
Martinique
Nordkorea
Litauen
Mexico
Pakistan
Luxembourg
Montserrat
Singapore
Malta
Nicaragua
Sri Lanka
Moldova
Panama
Sydkorea
Monaco
Puerto Rico
Taiwan
Montenegro
Saint Kitts og Nevis
Tajikistan
Nordmakedonien
Saint Lucia
Thailand
Norge
Saint Pierre og Miquelon
Turkmenistan
Østrig
Saint Vincent og Grenadinerne
Uzbekistan
Polen
Saint-Barthélemy
Vietnam
Portugal
Saint-Martin
Rumænien
Sint Maarten
Rusland
Trinidad og Tobago
San Marino
Turks- og Caicosøerne
Schweiz
USA
Serbien
Slovakiet
Slovenien
Spanien
Storbritannien
Sverige
Tjekkiet
Tyskland
Ukraine
Ungarn
Vatikanstaten