Veröffentlichen Sie Ihre Produkte
ASSA ABLOY VL3116 Hubtor
Archiviert

ASSA ABLOY VL3116 Hubtor

Das Gewebe-Hubtor ASSA ABLOY VL3116 wurde speziell für große Öffnungen, hohe Windbelastungen und schwierige Umweltbedingungen entwickelt. Der einzigartige Aufbau und die besondere Struktur haben sich besonders im maritimen Bereich bewährt und bieten hohe Betriebszuverlässigkeit bei minimalem Wartungsaufwand. Jedes Tor wird individuell auf die besonderen Anwendungsanforderungen zugeschnitten.
Spezifikation
  • Door leaf • Door leaf made out of two layers of very strong vinyl-coated polyester fabric, separated by aluminium intermediate sections. • Intermediate section which gives strength to the door leaf and which creates a buffer between the inside and outside fabric walls. • Wind load is transferred to the vertical guide rails by the horizontal aluminium sections of the door leaf. • The door leaf is available in 9 standard colours. • Door leaf thickness: 160 mm. • Aluminium guide rails. Bottom section • The bottom section, made of steel and aluminium, is connected to the lifting belt via the safety arresters. • The bottom section contains an optical safety edge and a rubber seal on the bottom edge that creates a seal between the door and the floor. • Optical safety edge. Safety arresters and wind lock in stainless steel • Safety arresters stop the door if the lifting belt becomes slack or, in an unlikely event, would break. • Wind lock system locks the door when the door is closed. Surface treatment • Steel components corrosion treatment: category 3 according to ISO 12944.2. Higher class on request. Aluminium, plastic, stainless steel, zinc electroplated steel (~10u). Fixing elements are mainly hot dip galvanized (FZV). Door leaf screws protected with Geomet. Standard door features • Door range: MIN: 6000mm x (no MIN. height) MAX: 14000 x 16000 mm • Normal operating speed of 0.2 - 0.3 m/sec • Temperature range: -35 °C to +70 °C • Compliance with all operational and safety instructions in EU Directives and the standards of the European Standardisation Committee (CEN) • Wind load (EN 12424) Class 2-5, 0.45-1.6 kPa, depending on size • Water resistance (EN 12425) Class 3, 0.11 kPa (for a closed door) • Air permeability (EN 12426) Class 2, 12 m3/(m2h) • Thermal transmittance (EN 12428) Depending on door size. Specific data on request. • Sound reduction (ISO 717) 15 dB Rw • Operating system: Electrical operator Dimensions: x mm (WxH) Options: Door leaf  Standard: Polyester, 1100 dtex with plasticised PVC coating  Option: Arctic fabric. For environmental temperatures down to -54°C  Option: Heat resistant fabric with silicone rubber coating  Option: Heat resistant fabric with aluminium coating  Option: Heat resistant fabric with aluminium polyurethane coating  Option: Sound reduction fabric  Option: Security fabric Vision panels  Width 800 mm, height between the intermediate profiles (depending on door size)  Width 1300 mm, height between the intermediate profiles (depending on door size) Fabric color  Beige (RAL 1001)  Red (RAL 3001)  Blue (RAL 5005)  Green (RAL 6009)  Grey (RAL 7004)  Anthracite (RAL 7016)  White (RAL 9016)  White aluminium (RAL 9006)  Translucent white Header box  Gear motor on inside of the building  Gear motor on outside of the building  Gear motor in the door opening  Insulated  Stainless steel cladding and motor casing  Self-supporting header box Operator • Control system PLC-based • Protection class, control cabinet IP65 • Protection class, limit switches IP67 • Protection class, motor brake IP55 • Protection class, push buttons IP65 • 3/phase 400V 50H power supply • Control voltage 24DC • Fusing: 20 A • Heat and cold resistance: -35 °C to +70 °C • Motor ratings: 2.8 - 5.0 kW Options  Free contacts: 6 for control of user functions  Radio remote control  “Open" (during closing process) if open button is used - door immediately stops and opens completely)  Pull switch for OPEN / CLOSE  External push-button, key switch  “One-button function” - opens or closes door, depending on actual status (e.g. radio, pull switch)  Additional safety (e.g. photo cell, radar)  Photo cell  Reduced opening height  Radar  Magnetic loop  Warning lights  Traffic lights  Interlocking door function Other supplementary equipment  Control cabinet in stainless steel  Heating element in the control cabinet  Emergency power switch with separate steel casing  Clamp strip covers in the same colors as the fabric  Side jambs (if posts for installing the guide rails are not available)  Side jambs in stainless steel  Wind deflectors (in combination with jambs)
Technische Spezifikation
  • Referenznummercra-vl-3116
  • TypObjekt (Einzelobjekt)
  • Veröffentlichungsdatum2017-08-29
  • Editionsnummer1
Verwandt
  • HauptmaterialStoff
  • Sekundär MaterialAluminium
Klassifikation
  • BIMobject KategorieTüren - Industrietore
  • IFCClassificationTür
  • UNSPSCNameDoors
  • UNSPSCCode301715
BIMobject-Produktbibliothek

Design App für Revit

Laden Sie Familien mit einem Klick direkt in Ihr Revit-Modell

Holen Sie sich einen Ort, um einfacher auf neue Objekte zuzugreifen, Ihre Revit-Familien zu speichern und mit Ihrem Team zusammenzuarbeiten.

  • HäkchenArbeiten Sie direkt mit BIM-Objekten neben Revit
  • Häkchen 2 GB Cloud-Speicher – speichern Sie Ihre Revit-Inhalte
  • Häkchen Holen Sie sich die verkörperte Kohlenstoff-LCA (A1-A3) direkt aus Revit