Automatic sliding door installation - standard
Gilgen automatic sliding door installation - standard
Gilgen automatic sliding door installation, TÜV-tested for conformity with EN 16005 and DIN 18650.
Gilgen SL sliding door drive unit in combination with Gilgen PSXP profile system.
The system as a whole has been tested for conformity with EN 16361 (corresponding to SIA 343).
Elegant integration, into the sliding door drive unit, of all actuating components, sensor elements and leaf profiles.
Digital control unit with touch-screen display. An electronic control unit with an automatic reversing and stopping mechanism provides gap-hazard detection. Suitable for connection via a BUS configuration or conventional wiring system.
Noise-insulated/vibration-damped drive system.
Low-noise toothed belt. Running carriage with counter-pressure rollers, height/depth-adjustable
( ) 100 mm drive case height
( ) 140 mm drive case height
( ) 140 mm drive case height for telescopic sliding door
Drive case covering
Standard: Hinge-type aluminium drive unit covering designed for easy service and maintenance access, with mechanical hold-open system and drop prevention.
Optional:
( ) Installation in false ceiling: Robust aluminium covering that can be removed from below.The drive case is fully integrated into the false ceiling.
( ) Lockable drive case covering with locking cylinder
Door leaves and fixed side panels
Clear height (mm): ……….
Clear width (mm): ……….
System configuration:
( ) Single leaf, left-handed
( ) Single leaf, right-handed
( ) Bi-parting
Configured as a telescopic sliding door:
( ) Two-leaf, left-handed
( ) Two-leaf, right-handed
( ) Four-leaf
Side panels:
( ) With fixed side panel(s)
( ) Without side panel
Protection leaves:
( ) Slimline, all-glass protection leaf in hinged configuration (designed for personal protection when opening the sliding door leaves). DO NOT use in conjunction with telescopic configuration!
Glazed overhead panel:
( ) Without glazed overhead panel
( ) With glazed overhead panel (one- to four-section)
Gilgen PSXP leaf profile system
All-round frame made of reinforced aluminium profiles. Upper door leaf profiles integrated into drive mechanism. Vertical interlocking between the sliding door leaves and side panels increases safety in the closed position, ensures stability and provides protection from draughts.
Dry glazing with rubber seals for the fast and simple replacement, when required, of glass or aluminium profiles. Glass thickness selectable from 6 mm to 24 mm.
Type of glass: ………………. / glass thickness: ………. (6 – 24 mm)
Surface treatment
( ) Powder-coated in RAL colours: …..
( ) Powder-coated in NCS colours: …..
( ) Aluminium, natural anodised finish E6/EV1
( ) Aluminium, coloured anodised finish. Colour code: …..
Bottom guide rail
( ) Lateral fixed-point guides
( ) With full length, flush-type rail embedded in floor, for reliable operation and increased resistance to wind pressure and forced opening. The door leaves are guided over the entire width and the guide rail is replaceable.
Optional:
( ) Heated bottom guideway to prevent the build-up of ice.
( ) Drained bottom guideway for systems exposed to the weather.
Drive/control system options
Emergency exit and rescue access
( ) Redundant configuration for use in emergency exits and rescue accesses. This TÜV-tested feature conforms to the latest standards (EN 16005 and DIN 18650), including those applicable to gap hazard detection and force limitation. Safety-critical control elements and components conform to Performance Level “d” in accordance with EN ISO 13849-1.
( ) Emergency opening in the event of power failure, by means of mechanical energy accumulator (RUBA, CO 48) designed for one single operation.
( ) Emergency operating mode
If the power supply fails, batteries ensure operation for a further 30 to 60 minutes. The system continuously monitors the battery's charge level to ensure that it will work in an emergency. The final door movement (opening or closing) in the event of low charge state can be programmed.
Additional control elements
( ) Voltage-free outputs for acknowledgements to, for example, the building management system (via interface PCB)
( ) Gilgen radio receiver and GFU hand-held transmitter
( ) Interlock operation between two Gilgen automatic door systems, programmable special functions (e.g. for wind protection in porch areas). The interlock function can be activated automatically or manually in controlled configuration or as a wind-protected porch system.
Locking mechanism
( ) Standard automatic locking system housed in drive case
( ) Multi-point locking mechanism fitted to leaf for added security
( ) Automatic
( ) Manual
Optional:
( ) Monitoring of the door leaf position and lock status TUWE (VdS), e.g. for connection to an alarm system.
( ) Manual internal release mechanism designed for installation in the frame profile, in a surface-mounted/flush-type box
( ) Manual internal release mechanism for installation in/on the side of the drive case. The customisable draw-bar length allows you to set an ideal operating height for barrier-free access.
( ) Release lever on door leaf (only in conjunction with multi-point locking)
( ) Lockable manual release from the outside for situations where there is no other access to the room.
Sensor system and user protection
( ) COMBISCAN-PI, integrated opening/safety sensor fitted inside the drive case. Motion detector and scanning safety barrier for the reliable monitoring of opening and closing movements. Meets the requirements for opening elements installed in the direction of escape (redundant emergency-exit configuration).
( ) COMBISCAN-PI, integrated opening/safety sensor fitted externally in the cover or carrier profile. Motion detector and scanning safety barrier for the reliable monitoring of opening and closing movements.
( ) COMBISCAN-SM, for surface-type installation on the lintel or façade. Opening and safety sensor. Motion detector and scanning safety barrier for the reliable monitoring of opening and closing movements. Meets the requirements for opening elements installed in the direction of escape (redundant emergency-exit configuration).
( ) SAFESCAN-PI, integrated safety sensor fitted inside the drive case. Scanning safety barrier for reliable monitoring of the secondary closing edge(s) during opening.
Operating controls
Digital control panel with illuminated touch-screen display, for selecting the door functions, adjusting all door parameters and displaying the operating data.
Control-panel installation:
( ) In drive case (fitted to control unit)
( ) With Feller Ediziodue flush-type plastic frame, white. For installation in embedded, flush-type box
( ) With Feller Ediziodue surface-type plastic frame, white. For surface installation
( ) KOMBI control panel with key cylinder mode selection AUTOMATIC NIGHT FUNCTION (for failsafe systems). Illuminated touch-screen display, for selecting the door function, adjusting all door parameters and displaying the operating data. Feller Ediziodue plastic frame, white.
( ) KOMBI control panel with key cylinder for blocking the selected operating mode. Illuminated touch-screen display, for selecting the door function, adjusting all door parameters and displaying the operating data. Feller Ediziodue plastic frame, white.
Installation of KOMBI control panel:
( ) With Feller Ediziodue flush-type plastic frame, white, for flush-type installation in twin box (depth 1 ½)
( ) With Feller Ediziodue surface-type plastic frame, white. For surface installation
Control/actuation elements
( ) Contactless ATC push-button for optimum hygienic operation
( ) OPEN push-button, white, from Feller EDIZIOdue
( ) OPEN push-button, green-lit, from Feller EDIZIOdue
( ) EMERGENCY OPEN push-button, green-lit, “emergency exit” symbol
( ) Key-operated OPEN impulse switch (pivoting switch)