Julkaise tuotteesi
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
    Wilkins

    975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern

    Ideal for use where Lead-Free* valves are required. Designed for installation on potable water lines to protect against both  backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. Model 975XL3N is for applications requiring vertical flow up and vertical flow down.

    Compliance:

    • ASSE® Listed 1013
    • AWWA Compliant C511
    • CSA® Certified B64.4
    • cUPC® Listed
    • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
      Meets the requirements of NSF/ANSI/CAN 61 & 372 *(LESS THAN 0.25% WEIGHTED AVERAGE LEAD CONTENT)

    Features:

    • N-pattern configuration with lay length designed for drop-in replacement of legacy irrigation and landscape backflow installations, reducing labor, materials, and enclosure rework.
    • All-bronze body ensures durability against the elements, with a Noryl®* check body and stainless-steel fasteners to resist corrosion over time.
    • Shares body, EZSWAP® modular checks, relief valve components, and repair kits with the 975XL3 platform for simple maintenance and stocking and service efficiency.
    • Test ports located on valve’s centerline make install and testing easy
    • Interlocking connected checks allow for ¼-turn access for fast disassembly and maintenance
    • Low-cost repair kits extend the lifespan at a significantly lower cost
    • Lead Free* bronze body (0.25% max. weighted average lead content) suitable for potable and irrigation applications.
    • ASSE Listed, UPC® Listed, Meets NSF/ANSI/CAN 61 & 372 requirements; Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California; Safe Drinking Water Act Compliant
    Tekniset tiedot
    • Yksilöity viite975XL3N
    • TuoteperheBackflow Preventers
    • TuoteryhmäReduced Pressure Principle Assembly
    • TyyppiObjekti (yksittäinen objekti)
    • Julkaisupäivä2026-04-10
    • Painoksen numero1
    Liittyviä
    • Suunniteltu:Yhdysvallat
    Luokitus
    • BIMobject-luokkaPutkityöt - Venttiilit

    Alueellinen saatavuus

    Pohjois-Amerikka
    Anguilla
    Antigua ja Barbuda
    Aruba
    Bahamasaaret
    Barbados
    Belize
    Bermuda
    Brittiläiset Neitsytsaaret
    Caribbean Netherlands
    Caymansaaret
    Costa Rica
    Curaçao
    Dominica
    Dominikaaninen tasavalta
    El Salvador
    Grenada
    Grönlanti
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaika
    Kanada
    Kuuba
    Martinique
    Meksiko
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Kitts ja Nevis
    Saint Lucia
    Saint Vincent ja Grenadiinit
    Saint-Barthélemy
    Saint-Martin
    Saint-Pierre ja Miquelon
    Sint Maarten
    Trinidad ja Tobago
    Turks- ja Caicossaaret
    Yhdysvallat
    Yhdysvaltain Neitsytsaaret
    Common.Footer.ValueProp.Image.AltText

    Design App for Revit

    Lataa perheet suoraan Revit-malliisi yhdellä napsautuksella

    Hanki paikka, jossa voit käyttää uusia objekteja helpommin, tallentaa Revit-perheesi ja tehdä yhteistyötä tiimisi kanssa.

    • ValintamerkkiTyöskentele suoraan BIM-objektien kanssa Revitin vieressä
    • Valintamerkki 2 Gt pilvitallennustilaa – tallenna Revit-sisältösi
    • Valintamerkki Hanki sisällysluettelon hiilijalanjälkilaskenta (A1–A3) suoraan Revitistä