Publier vos produits
VK188 - EC/QREC Dry Horizontal Sidewall Sprinkler (K5.6)
Archivé

VK188 - EC/QREC Dry Horizontal Sidewall Sprinkler (K5.6)

Viking Standard/Quick Response Extended Coverage Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant. Refer to the technical data sheet for design and installation requirements.
Spécification
  • K-Factor: K5.6 (80)

    Manufacturer: Viking

    Page: F_051598

    Part Number: 10542U

    VK Number: VK188

    Additional Information: NOTICE: The product details indicated below are for general reference only and may vary based on the specific product approval and/or application. Always verify product details with the technical data sheet and consult with the Authority Having Jurisdiction (AHJ).

    Max Pressure: 175 psi (12 bar)

    Response Type: Quick Response (See Listing)

    Occupancy Type: Light

    Thread Size: 1" NPT (25 mm BSP)

    Min Spacing: Per Standards / Listings

    Max Spacing: 16 x 20 ft (4,9 x 6,1 m)

Spécifications techniques
  • Réference unique.vk188-quick-response-horizontal-sidewall-sprinkler-k56
  • Famille de produitsViking Dry Barrel Sprinklers
  • Groupe de produitsViking - Dry HSW Recessed Esc / Horizontal Sidewall
  • TypeObjet (objet simple)
  • Date de publication2021-01-25
  • Numéro d'édition1
En rapport
  • Conçu enÉtats-Unis
  • Fabriqué enÉtats-Unis
Classification
  • BIMobject CatégorieSécurité Incendie - Système de Sprinklers
  • Code ETIMEC011373
  • Nom ETIMDry sprinkler
  • Nom UNSPSCFire sprinkler heads
  • Code UNSPSC46191610
  • Code Uniclass 2015Pr_70_55_97_84
  • Description de l'Uniclass 2015Sprinkler heads
  • Code CSI MasterFormat 201421 13 00
  • Titre CSI MasterFormat 2014Fire-Suppression Sprinkler Systems
  • Numéro OmniClass23-29 33 11 15 13
  • Titre OmniClassDry Side Wall Sprinkler Heads
  • Code CSI UniFormat IID4010
  • Titre CSI UniFormat IISprinklers
Common.Footer.ValueProp.Image.AltText

Application Design pour Revit

Chargez des familles directement dans votre modèle Revit en un seul clic

Bénéficiez d'un endroit pour accéder plus facilement à de nouveaux objets, stocker vos familles Revit et collaborer avec votre équipe.

  • CocheTravaillez directement avec des objets BIM à côté de Revit
  • Coche 2 Go de stockage dans le cloud : stockez votre contenu Revit
  • Coche Obtenez une analyse du cycle de vie du carbone incorporé (A1-A3) directement depuis Revit