Pubblica i tuoi prodotti
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26
BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26

    BE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC_Rvt26

    The warm roof (or unventilated roof) is a system that does not require a ventilation gap under the zinc. The zinc is therefore installed directly onto its support. This implies the use of ZINC PLUS. It is recommended to place the VMZINC Membrane between the ZINC PLUS and the insulation. VMZINC's ZINC PLUS is coated on its underside with a white organic protective layer. While ZINC PLUS can withstand light condensation, it must under no circumstances be continuously exposed to standing water; therefore, the installation of the vapor barrier must be flawless.

    The standing seam is aesthetic, modern, and offers uniform, low-profile joints (25 mm high with a thickness of 5 mm).

    Packaging:
    The zinc is delivered in rolls to be profiled or in preformed strips on demand.

    Surface aspects: QUARTZ-ZINC® PLUS / ANTHRA-ZINC® PLUS / PIGMENTO® PLUS (blue, red, green, brown) / Bilacquered ZINC PLUS® / AZENGAR® PLUS / NATURAL ZINC

    The use of the chosen aspect may not be suitable for certain applications in the context of very aggressive environmental constraints. It is recommended, if necessary, to consult the VM Building Solutions services for further information.

    Voce di capitolato
    • Application:

      All types of roofs. All shapes: Flat, curved, concave, convex, conical, domes.

      New build & renovation, simple or complex shapes.

      Pitches: For roofs from 3° (5%) to 75°, the boarding (sheathing) is continuous and spaced 3 to 5 mm apart.

      Standard Dimensions:

      Effective width: 430 / 530 / 600 mm

      VMZINC Standing Seam height: 25 mm

      Sheet length: 10 m; however, experience shows that for roofing, provided specific installation of the fixing clips is used, strips up to 13 m can be installed.

      Fixings:

      The sliding clips are fixed through the insulation into the steel decks/panels using stainless steel self-drilling screws, which can be supplied by VM Building Solutions nv. The length of the screw must be at least 20 mm greater than the insulation thickness and must not exceed the overall system thickness (insulation + steel deck/panels) by more than 60 mm / 30 mm.

      For projects located less than 3 km from the coast, these screws must be made of grade A4 stainless steel. Further inland, they can be made of galvanized steel in compliance with NF A 35-551 standards.

      Climates:

      All wind regions. The choice by a professional of a VMZINC® product from VM Building Solutions must integrate the possible constraints of use according to the surface aspect considered. Each aspect of the zinc surface can change over time in different ways depending on the type of environment (seaside, high UV exposure, snow, etc.) and according to the applications (roofing, facade, rainwater drainage). The use of the chosen aspect may not be suitable for certain applications in the context of very aggressive environmental constraints. It is recommended, if necessary, to consult VM Building Solutions services for further information.

      Reference Documents: Recommendations from Buildwise NIT 266.

      Fire Resistance: Complies with Broof(t1).

    Specifiche tecniche
    • Rif. UnicoBE_fr_Joint_debout_Toiture_chaude_PIR_PUR_VMZINC
    • Famiglia di prodottoCouverture
    • Gruppo di famigliaVMZINC ROOFING
    • TipoOggetto (oggetto singolo)
    • Data di pubblicazione2026-06-09
    • Numero di versione1
    Relativo a
    • Materiale principaleMetallo
    • Materiale secondarioIsolamento
    • Progettato inFrancia
    • Prodotto inFrancia
    Classificazioni
    • Categoria BIMobjectEdilizia - Coperture, tetti e tegole
    • Clasificazione IFCTetto
    • Nome UNSPSCRoofing materials
    • Codice UNSPSC301515
    • Codice Uniclass 2015Ss_30_40_50_95
    • Descrizione Uniclass 2015Zinc sheet roof covering systems
    • Codice CSI MasterFormat 201407 41 13
    • Titolo CSI MasterFormat 2014Metal Roof Panels
    • Numero OmniClass23-13 39 11 11
    • Titolo OmniClassExterior Metal Roof Panels
    • Codice CSI UniFormat IIB3010
    • Titolo CSI UniFormat IIRoof Coverings

    Disponibilità Regionale

    Europa
    Belgio
    Lussemburgo
    Paesi Bassi
    Common.Footer.ValueProp.Image.AltText

    App di progettazione per Revit

    Carica le famiglie direttamente nel tuo modello Revit con un solo clic

    Ottieni un posto per accedere più facilmente a nuovi oggetti, archivia le tue famiglie Revit e collabora con il tuo team.

    • Segno di spuntaLavora direttamente con gli oggetti BIM accanto a Revit
    • Segno di spunta 2 GB di spazio di archiviazione cloud: archivia i tuoi contenuti Revit
    • Segno di spunta Ottieni l'LCA (A1-A3) del carbonio incorporato direttamente da Revit