    Wilkins FCIS Connected Flood Control System

    The Connected Flood Control System (Model FCIS) shall consist of a Reduced Pressure Principle Assembly (RP) (Model 375ASTW1, 375AW1, 375W1), a Solenoid Control Valve(SCV) (Model ZW206), and a Zurn Relief Valve Monitor and shall be constructed and tested at the factory as a complete assembly. The RP shall be certified to NSF/ANSI/CAN 61 & 372, and shall be ASSE 1013 Listed. The RP shall be furnished with full port, resilient seated shut-off valves, and shall be equipped with an integral Relief Valve Monitor that monitors the Relief Valve in a closed position. The seat ring and the check valves shall be Noryl, the stems and springs shall be Stainless Steel, and the elastomers shall be EPDM. The SCV shall be a single seated, line-pressure-operated, diaphragm-actuated, pilot-controlled valve. The SCV shall seal by means of a corrosion-resistant seat and a resilient, rectangular seat disc. The stem of the SCV shall be guided top and bottom by integral bushings, and shall contain no packing glands or stuffing boxes. The SCV shall be protected with internal and external FDA approved epoxy coating, and the diaphragm shall not be used as a seating surface. The Relief Valve Monitor shall have an input voltage of 120 VAC, and shall be provided with an output of 24 VDC controlled by a relay. The Relief Valve Monitor shall be housed in a water-tight NEMA enclosure, and shall have both normally open and normally closed outputs. The three components, the RP, SVC, and Relief Valve Monitor, when combined together, automatically shut off the water supply in the event of catastrophic relief valve discharge. The Reduced Pressure Principle Assembly, Solenoid Control Valve, and assembled as a complete unit shall be the WILKINS FCIS.

    Compliance:

    • NSF Standard 61
    • NSF Standard 372
    • ASSE® Listed 1013
    • CSA® Certified B64.4
    • cUPC listed
    • UL listed
    • IPC listed
    • NPCC listed
    • Product USC Approved
    • Product FM Approved

    Features:

    • Ideal for installation in areas not immediately visible where undetected relief valve discharge could potentially cause catastrophic flooding and water damage.
    • Automatic shutoff of the water system reduces potential for costly flooding damage
    • 24/7 relief water discharge data provides secure real-time monitoring and notifications
    • Customizable water shutoff timer
    • The pre-wired FCIS package includes a Model 375W1, 375AW1 or 375ASTW1 
    • Reduced Pressure Principle Backflow Preventer and is attached to a Model ZW206 ACV Solenoid Control Valve.
    • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
    • Reduced Pressure Principle Assembly is AWWA compliant C511 (with gates only ) and C550
    Voce di capitolato
    • Zurn Connected Flood Control Systems transmit data 24/7 to the Zurn plumbSMART™ web portal and mobile app. Proactively monitor your relief water discharge and optional system pressure data, receive real-time alerts for relief valve discharge occurrences, and access system data for trends and predictive maintenance anytime and anywhere. Zurn Connected Flood Control Systems are designed to prevent flooding of a building caused by discharge from a catastrophically fouled Reduced Pressure Principle backflow preventer. The pre-wired FCIS package includes a Model 375W1 Reduced Pressure Principle Backflow Preventer that detects relief valve discharge in real-time, and is attached to a Solenoid Control Valve to shut off the water supply when excessive discharge happens using a built-in relief valve position switch with adjustable time delay.

    Specifiche tecniche
    • Rif. Unicozurn-fcis
    • Famiglia di prodottoBackflow Preventers
    • Gruppo di famigliaReduced Pressure Principle Assembly, Detector
    • TipoOggetto (oggetto singolo)
    • Data di pubblicazione2025-09-02
    • Numero di versione1
    • Altezza (pollici)27.25
    • Larghezza (pollici)14.25
    • Profondità (pollici)43
    Relativo a
    • Materiale principaleDuctile Iron
    • Materiale secondarioAcciaio inossidabile
    • Progettato inStati Uniti
    • Peso Netto (Libbre)153
    Classificazioni
    • Categoria BIMobjectImpianto idraulico - Valvole

    Disponibilità Regionale

    Nord America
    Anguilla
    Antigua e Barbuda
    Aruba
    Bahamas
    Barbados
    Belize
    Bermuda
    Canada
    Costa Rica
    Cuba
    Curaçao
    Dominica
    El Salvador
    Giamaica
    Grenada
    Groenlandia
    Guadalupa
    Guatemala
    Haiti
    Honduras
    Isole BES
    Isole Cayman
    Isole Turks e Caicos
    Isole Vergini Americane
    Isole Vergini britanniche
    Martinica
    Messico
    Montserrat
    Nicaragua
    Panamá
    Porto Rico
    Repubblica Dominicana
    Saint Kitts e Nevis
    Saint Martin
    Saint Vincent e Grenadine
    Saint-Barthélemy
    Saint-Pierre e Miquelon
    Santa Lucia
    Sint Maarten
    Stati Uniti
    Trinidad e Tobago
    Common.Footer.ValueProp.Image.AltText

    App di progettazione per Revit

    Carica le famiglie direttamente nel tuo modello Revit con un solo clic

    Ottieni un posto per accedere più facilmente a nuovi oggetti, archivia le tue famiglie Revit e collabora con il tuo team.

    • Segno di spuntaLavora direttamente con gli oggetti BIM accanto a Revit
    • Segno di spunta 2 GB di spazio di archiviazione cloud: archivia i tuoi contenuti Revit
    • Segno di spunta Ottieni l'LCA (A1-A3) del carbonio incorporato direttamente da Revit