제품 게시
Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor, Stainless Steel – Sizes 2 1/2 – 10 IN - 957RPDA-FS
Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor, Stainless Steel – Sizes 2 1/2 – 10 IN - 957RPDA-FS
Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor, Stainless Steel – Sizes 2 1/2 – 10 IN - 957RPDA-FS
Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor, Stainless Steel – Sizes 2 1/2 – 10 IN - 957RPDA-FS
Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor, Stainless Steel – Sizes 2 1/2 – 10 IN - 957RPDA-FS
    Watts

    Reduced Pressure Detector Assembly Backflow Preventers with Flood Sensor, Stainless Steel – Sizes 2 1/2 – 10 IN - 957RPDA-FS

    Series 957RPDA-FS reduced pressure detector assembly backflow preventers help stop the reverse flow of fire protection system substances being pumped or siphoned into the potable water supply. A meter incorporated to detect ground leaks and unauthorized illegal taps greatly reduces annual water expenses. Maximum Working Pressure: 175 psi (12.06 bar).

    This series features an integrated flood sensor with SentryPlus™ Alert technology to detect excessive water discharges from the relief valve. Activated through an add-on connection kit, the sensor can trigger the alert system sending notification of flood detection to facility personnel. Connection kits are available for BMS and cellular communication.

    사양
    • Features

      • Flood alert feature available with add-on connection kit, compatible with BMS and cellular communication
      • Extremely compact stainless steel body with stainless steel internal parts
      • Ideal for health hazard cross-connection such as on fire sprinkler systems
      • Available with quarter-turn ball valve shutoffs or grooved butterfly valve shutoffs
      • Torsion spring checks providing the lowest pressure loss
      • Lightweight stainless steel construction (70% lighter than traditional designs)
      • Integrated sensor on relief valve for flood detection

      Keywords: 110v, 200wog, 220v, airgap, assembly, backflow, backflow preventer valve, backflow valve, bacteria water filtration, bonnet, brass, bypass, cap, cfm, check, checkvalve, cover, crosshandle, dcda, detector, discharge, double check, doublecheck, drain, gatevalve, gpm, ips, ironpipe, kit, lead free, meter, osy, plastic, pressure valve, pressure zone valve, preventer, rdza, reduced pressure, reduced pressure detector, reduced pressure valve, releif, repair, rp, rpda, rubber, seat, shut-off, stainless steel, stainless steel body, tamper switch, thread, thread protector, threaded, ultraviolet water filtration, uv filtration, valve, vlv, water disinfection, water filtration, watts

    기술 사양
    • 특징 참조957RPDA-FS
    • 제품군Backflow Prevention
    • 제품분류Non-Return Valves for Liquid Services
    • 유형개체 (단일 개체)
    • 게시일2022-12-21
    • 에디션 넘버1
    관련성
    • 설계국가미국
    • 제조국가미국