제품 게시
Wilkins 375 Reduced Pressure Principle Backflow Preventer, 1/2" to 2"
Wilkins

Wilkins 375 Reduced Pressure Principle Backflow Preventer, 1/2" to 2"

Designed for installation on irrigation water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. For non-potable applications only.

Compliance:

  • ASSE® Listed 1013
  • cUPC® Listed
  • CSA® Certified B64.4
  • AWWA Compliant C511
    • Approved by the Foundation for Cross Connection Control and Hydraulic
    Research at the University of Southern California

Features:

  • EZSwap® Pressure Vessel is removable for easy access and added convenience
  • Flush Tool (FLUSH) provides easy line flushing, saving up to 15 minutes per installation
  • Durable UV resistant reinforced nylon EZSwap Pressure Vessel resists corrosion and mineral build-up to better withstand harsh conditions
  • Minimal bronze construction acts as theft deterrent
  • High pressure rating of 175 psi
  • ASSE listed 1013 and IAPMO listed
  • CSA Certified B64.4
사양
  • The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180°F and supplied with full port ball valves. The main body shall be Nylon and the seat disc elastomers shall be silicone. If installed indoors, the installation shall be supplied with an air gap adapter. For non-potable applications only. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 375.

    keywords: Backflow Preventers,Lead-Free Products,Zurn Wilkins Water Control,Government Buildings,Commercial,High Rise Buildings,Hospitality,Military,Office,Retail,Healthcare,School Systems,Educational Facilities,Universities,Power Generation,Industrial,Irrigation,Architectural/Aesthetics,Development,Civil,Transportation,Correctional/Institutional,Fire Protection,Food Service,Industrial/Processing Plant,Light Commercial,Residential Multi-Family,Residential/Light Commercial,Sports Complex/Recreational Center,Waterworks,Reduced Pressure Principle Assembly,Zurn Wilkins Backflow Preventers,Lead-Free Law Compliance,MasterSpec,Retrofit and Replacement,Water Conservation,Zurn Wilkins,,75,5

기술 사양
  • 특징 참조zurn-375sm
  • 제품군Backflow Preventers
  • 제품분류Reduced Pressure Principle Assembly
  • 유형개체 (단일 개체)
  • 게시일2025-09-02
  • 에디션 넘버1
관련성
  • 주 재료나일론
  • 부 재료스테인레스강
  • 설계국가미국
분류
  • BIMobject 카테고리배관 - 밸브

지역 가용성

북미
과들루프
과테말라
그레나다
그린란드
네덜란드령 카리브 해 지역
니카라과
도미니카
도미니카 공화국
마르티니크
멕시코
몬세라트
미국
미국령 버진아일랜드
바베이도스
바하마
버뮤다
벨리즈
생마르탱
생바르텔레미
생피에르앤드미클롱
세인트루시아
세인트빈센트그레나딘
세인트키츠네비스
신트마르턴
아루바
아이티
앤티가 바부다
앵귈라
엘살바도르
영국령 버진아일랜드
온두라스
자메이카
캐나다
케이맨 군도
코스타리카
쿠바
퀴라소
터크스케이커스 제도
트리니다드토바고
파나마
푸에르토리코