Opublikuj swoje produkty
Hurricane Miami-Dade Louver - 5" Deep - 45 Degree Chevron Blade - Extruded Aluminum - ECD-545-MD
Pottorff

Hurricane Miami-Dade Louver - 5" Deep - 45 Degree Chevron Blade - Extruded Aluminum - ECD-545-MD

Extruded Aluminum Louver
5" Deep - 45 Degree Horizontal Blade

The ECD-545-MD is engineered and tested to withstand extreme loads, debris impact, and cyclic fatigue associated with the severe weather effects of hurricanes (Miami-Dade County approval #21-1122.06). When combined with the optional factory-attached CD-51 damper in the closed position, the ECD-545-MD also protects against high-velocity wind-driven rain per AMCA 550 and TAS 100A.

Opis
  • Standard Construction

    Material: Mill finish 6063-T5 extruded aluminum.

    Frames: 5" deep x 0.125" thick (127 x 3) channel.

    Blades: 45o x 0.063" (1.6) thick horizontal chevron style.

    Screen: 1/2" x 0.063" (12.7 x 1.6) expanded and flattened aluminum.

    Mullion: Visible.

    Minimum Size:
    6" x 6" (152 x 152)
    12" x 14" (305 x 356) with CD-51 option

    Maximum Size:
    Single Section: 60" x 144" (1524 x 3658)
    Multiple Section: Unlimited width x 144" (3658) or 60" (1524) x unlimited height


    Ratings

    Free Area: 6.7 ft2 (0.62 m2)

    Performance @ Beginning Point of Water Penetration

    Free Area Velocity: 1250 fpm (6.35 m/s)

    Air Volume Delivered: 8388 cfm (3.96 m3/s)

    Pressure Loss: 0.21 in. wg. (52 Pa)

    Velocity @ 0.15 in. wg. Pressure Loss: 1057 fpm (5.37 m/s)

    Design Load: 150 psf

    AMCA 540 and 550 Listed
    AMCA Certified for Water Penetration, Air Performance and Wind-Driven Rain
    Miami Dade County Approved: NOA No. 21-1122.06
    Florida Building Code Approved (2020-FBC): No. FL17876.1

Specyfikacja techniczna
  • Nr referencyjnyHurricane-Miami-Dade-Louver-5-Deep-45-Degree-Chevron-Blade-Extruded-Aluminum-ECD-545-MD
  • Rodzina produktuHVAC
  • Grupa produktuLouvers and Penthouses
  • TypObiekt (jeden obiekt)
  • Data publikacji2024-07-16
  • Numer edycji1
Klasyfikacja
  • Kategoria BIMobjectHVAC - Przewody
  • Uniclass 2015 CodePr_30_59_48
  • Uniclass 2015 DescriptionLouvres and components
  • CSI MasterFormat 2014 Code08 91 00
  • CSI MasterFormat 2014 TitleLouvers
  • OmniClass Number23-33 29 31
  • OmniClass TitleLouvre Dampers

Dostępny w krajach:

Ameryka północna
Anguilla
Antigua i Barbuda
Aruba
Bahamy
Barbados
Belize
Bermudy
Brytyjskie Wyspy Dziewicze
Curaçao
Dominika
Dominikana
Grenada
Grenlandia
Gwadelupa
Gwatemala
Haiti
Holandia Karaibska
Honduras
Jamajka
Kajmany
Kanada
Kostaryka
Kuba
Martynika
Meksyk
Montserrat
Nikaragua
Panama
Portoryko
Saint Kitts i Nevis
Saint Lucia
Saint Martin
Saint Vincent i Grenadyny
Salwador
Sint Maarten
Stany Zjednoczone
Trynidad i Tobago
Turks i Caicos
Wspólnota Saint-Barthélemy
Wspólnota Terytorialna Saint Pierre i Miquelon
Wyspy Dziewicze
Common.Footer.ValueProp.Image.AltText

Aplikacja Design App dla Revit

Wczytaj rodziny bezpośrednio do modelu Revit jednym kliknięciem

Zyskaj łatwiejszy dostęp do nowych obiektów, przechowuj rodziny Revit i współpracuj ze swoim zespołem.

  • Zaznacz pole wyboruPracuj bezpośrednio z obiektami BIM obok Revit
  • Zaznacz pole wyboru 2 GB miejsca w chmurze — przechowuj zawartość Revit
  • Zaznacz pole wyboru Uzyskaj wbudowany węgiel LCA (A1-A3) bezpośrednio z Revit