Opublikuj swoje produkty
Wilkins FCIS Connected Flood Control System
Wilkins FCIS Connected Flood Control System
Wilkins FCIS Connected Flood Control System
    Wilkins

    Wilkins FCIS Connected Flood Control System

    The Connected Flood Control System (Model FCIS) shall consist of a Reduced Pressure Principle Assembly (RP) (Model 375ASTW1, 375AW1, 375W1), a Solenoid Control Valve(SCV) (Model ZW206), and a Zurn Relief Valve Monitor and shall be constructed and tested at the factory as a complete assembly. The RP shall be certified to NSF/ANSI/CAN 61 & 372, and shall be ASSE 1013 Listed. The RP shall be furnished with full port, resilient seated shut-off valves, and shall be equipped with an integral Relief Valve Monitor that monitors the Relief Valve in a closed position. The seat ring and the check valves shall be Noryl, the stems and springs shall be Stainless Steel, and the elastomers shall be EPDM. The SCV shall be a single seated, line-pressure-operated, diaphragm-actuated, pilot-controlled valve. The SCV shall seal by means of a corrosion-resistant seat and a resilient, rectangular seat disc. The stem of the SCV shall be guided top and bottom by integral bushings, and shall contain no packing glands or stuffing boxes. The SCV shall be protected with internal and external FDA approved epoxy coating, and the diaphragm shall not be used as a seating surface. The Relief Valve Monitor shall have an input voltage of 120 VAC, and shall be provided with an output of 24 VDC controlled by a relay. The Relief Valve Monitor shall be housed in a water-tight NEMA enclosure, and shall have both normally open and normally closed outputs. The three components, the RP, SVC, and Relief Valve Monitor, when combined together, automatically shut off the water supply in the event of catastrophic relief valve discharge. The Reduced Pressure Principle Assembly, Solenoid Control Valve, and assembled as a complete unit shall be the WILKINS FCIS.

    Compliance:

    • NSF Standard 61
    • NSF Standard 372
    • ASSE® Listed 1013
    • CSA® Certified B64.4
    • cUPC listed
    • UL listed
    • IPC listed
    • NPCC listed
    • Product USC Approved
    • Product FM Approved

    Features:

    • Ideal for installation in areas not immediately visible where undetected relief valve discharge could potentially cause catastrophic flooding and water damage.
    • Automatic shutoff of the water system reduces potential for costly flooding damage
    • 24/7 relief water discharge data provides secure real-time monitoring and notifications
    • Customizable water shutoff timer
    • The pre-wired FCIS package includes a Model 375W1, 375AW1 or 375ASTW1 
    • Reduced Pressure Principle Backflow Preventer and is attached to a Model ZW206 ACV Solenoid Control Valve.
    • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
    • Reduced Pressure Principle Assembly is AWWA compliant C511 (with gates only ) and C550
    Opis
    • Zurn Connected Flood Control Systems transmit data 24/7 to the Zurn plumbSMART™ web portal and mobile app. Proactively monitor your relief water discharge and optional system pressure data, receive real-time alerts for relief valve discharge occurrences, and access system data for trends and predictive maintenance anytime and anywhere. Zurn Connected Flood Control Systems are designed to prevent flooding of a building caused by discharge from a catastrophically fouled Reduced Pressure Principle backflow preventer. The pre-wired FCIS package includes a Model 375W1 Reduced Pressure Principle Backflow Preventer that detects relief valve discharge in real-time, and is attached to a Solenoid Control Valve to shut off the water supply when excessive discharge happens using a built-in relief valve position switch with adjustable time delay.

    Specyfikacja techniczna
    • Nr referencyjnyzurn-fcis
    • Rodzina produktuBackflow Preventers
    • Grupa produktuReduced Pressure Principle Assembly, Detector
    • TypObiekt (jeden obiekt)
    • Data publikacji2025-09-02
    • Numer edycji1
    • Wysokość (cale)27.25
    • Szerokość (cale)14.25
    • Głębokość (cale)43
    Dodatkowe informacje
    • Materiał głównyDuctile Iron
    • Materiał dodatkowyStal nierdzewna
    • Zaprojektowano wStany Zjednoczone
    • Waga netto (lbs)153
    Klasyfikacja
    • Kategoria BIMobjectHydraulika - Zawory

    Dostępny w krajach:

    Ameryka północna
    Anguilla
    Antigua i Barbuda
    Aruba
    Bahamy
    Barbados
    Belize
    Bermudy
    Brytyjskie Wyspy Dziewicze
    Curaçao
    Dominika
    Dominikana
    Grenada
    Grenlandia
    Gwadelupa
    Gwatemala
    Haiti
    Holandia Karaibska
    Honduras
    Jamajka
    Kajmany
    Kanada
    Kostaryka
    Kuba
    Martynika
    Meksyk
    Montserrat
    Nikaragua
    Panama
    Portoryko
    Saint Kitts i Nevis
    Saint Lucia
    Saint Martin
    Saint Vincent i Grenadyny
    Salwador
    Sint Maarten
    Stany Zjednoczone
    Trynidad i Tobago
    Turks i Caicos
    Wspólnota Saint-Barthélemy
    Wspólnota Terytorialna Saint Pierre i Miquelon
    Wyspy Dziewicze
    Common.Footer.ValueProp.Image.AltText

    Aplikacja Design App dla Revit

    Wczytaj rodziny bezpośrednio do modelu Revit jednym kliknięciem

    Zyskaj łatwiejszy dostęp do nowych obiektów, przechowuj rodziny Revit i współpracuj ze swoim zespołem.

    • Zaznacz pole wyboruPracuj bezpośrednio z obiektami BIM obok Revit
    • Zaznacz pole wyboru 2 GB miejsca w chmurze — przechowuj zawartość Revit
    • Zaznacz pole wyboru Uzyskaj wbudowany węgiel LCA (A1-A3) bezpośrednio z Revit