The Pressure Reducing Valve shall be certified to NSF/ANSI/CAN 61, consisting of a low lead bronze body and bronze bell housing, a separate access cover for the plunger and a bolt to adjust the downstream pressure. The bronze bell housing and access cap shall be threaded to the body and shall not require the use of ferrous screws. The assembly shall be of the balanced piston design and shall reduce pressure in both flow and no-flow conditions. The assembly shall be accessible for maintenance without having to remove the body from the line. The Pressure Reducing Valve shall be a WILKINS Model 500XLYSBR.
Compliance:
• ASSE® Listed 1003 (1/2” thru 2 1/2”)
• cUPC® Listed (1/2” thru 2”)
• CSA® Certified B356 (1/2” thru 2”)
• City of Los Angeles Approved (1/2” thru 2”)
• Meets the requirements of NSF/ANSI/CAN 61 and 372*
*(Less Than 0.25% Weighted Average Lead Content)
Features: