Публікуйте свої продукти
myRoom XC Guestroom Wireless Processor
myRoom XC Guestroom Wireless Processor
    Lutron Electronics

    myRoom XC Guestroom Wireless Processor

    The guestroom wireless processor integrates Clear Connect – Type X devices (such as Ketra loads) with Clear Connect – Type A devices (such as Pico wireless controls and Radio Powr Savr sensors).

    Зв’яжіться з Lutron Electronics

    Специфікація
    • Each guestroom wireless processor can communicate with the following: 

      • Clear Connect - Type X devices (100 maximum)– Commercial Ketra Type X loads– Sunnata dimmers / switches / keypads– Lumaris RGB + Tunable White tape light – Athena wireless nodes– Rania D2 

      • Clear Connect - Type A devices (50 maximum)– Pico wireless controls– Radio Powr Savr occupancy/vacancy sensors (15 maximum) Features 

      • Powered by an IEEE 802.3af, IEEE 802.3at or IEEE 802.3bt compliant LPS / SELV PoE or PoE+ power supply, Lutron model L-POEI-BL or by others (sold separately). 

      • Timeclock scheduling of daily events. 

      • Connects to the network via an Ethernet connection. 

      • Local device operation will continue to function if internet connection is lost.

      Specifications 

      Regulatory Approvals • cULus • FCC • IC • NOM • IFTEL 

      PoE Power • Processor is an IEEE 802.3af compliant Class 1 device; typical 1.5 W (max 4.0 W) • 48 V- 100 mA (IEEE 802.3af, IEEE 802.3at or IEEE 802.3bt compliant LPS / SELV PoE or PoE+) • Compatible power supply: L-POEI-BL available for purchase separately, or IEEE 802.3af, IEEE 802.3at or IEEE 802.3bt compliant LPS / SELV PoE or PoE+ supply by others 

      Environment • Operating temperatures 32 °F to 104 °F (0 °C to 40 °C) • Relative humidity: 0% to 90% non-condensing • For indoor use only 

      ESD Protection • Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2. 

      Surge Protection • Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice for Surge Voltages in Low-Voltage AC Power Circuits. 

      Power Failure • 10-year power failure memory: Should the power be interrupted, the wireless processor will return to its previous state prior to the interruption when power is restored.

      Mounting • The guestroom wireless processor can be recess-mounted or wall-mounted using the included recess bracket or junction box bracket in a nonmetal ceiling tile or drywall. When mounting on a 4 in x 4 in (102 mm x 102 mm) junction box, a mud ring (not supplied) must be used. • The guestroom wireless processor can also be shelf-mounted using the L-SMNT-WH (sold separately). • The guestroom wireless processor and Clear Connect - Type X devices must be mounted 5 ft (1.5 m) away from wireless interference sources like microwaves, Wireless Access Points (WAP), etc. • Do not install the guestroom wireless processor in metallic enclosures. • Do not install the guestroom wireless processor above metal ceilings or tiles with metal backing. 

      Wiring • Use Cat5e minimum cable. Maximum length is 328 ft (100 m) from router to processor. Each wireless processor needs to have a home run Ethernet connection back to the PoE supply. • PoE wiring must be kept internal to the building. Do not run PoE wiring outdoors

    Технічна специфікація
    • Унікальний номерlutron-myroomxc-rf2-gcu
    • Сімейство продуктівLighting Controls
    • Група продуктівmyRoom XC
    • ТипObject (single object)
    • Дата публікації2026-04-17
    • Номер видання1
    • Висота (у дюймах)4.04
    • Ширина (у дюймах)4.04
    • Глибина (у дюймах)1.17
    Пов'язані
    • Матеріал основнийPlastic
    Класифікація
    • Категорія BIMobjectЕлектричні - Controls
    Common.Footer.ValueProp.Image.AltText

    Design App для Revit

    Завантажуйте сімейства безпосередньо у вашу модель Revit одним кліком

    Отримайте місце для легшого доступу до нових об’єктів, зберігайте свої сімейства Revit і співпрацюйте зі своєю командою.

    • ГалочкаПрацюйте безпосередньо з об'єктами BIM поруч із Revit
    • Галочка 2 ГБ хмарного сховища - зберігайте свій вміст Revit
    • Галочка Отримайте LCA (A1-A3) втіленого вуглецю прямо з Revit