發佈您的產品
Model 8000 Commercial RiserPACK® - Prepackage Commercial Riser Assembly

Model 8000 Commercial RiserPACK® - Prepackage Commercial Riser Assembly

4.6 星(最高 5 星)4.6(7 評價)

The Model 8000 Commercial RiserPACK® is a prepackaged economical riser assembly designed for NFPA 13 wet fire sprinkler systems. The Commercial Model 8000 is available in two different riser styles and seven different size/connection combinations:

Bronze Riser:

  • 1-1/4", 1-1/2", 2" NPT
  • 1-1/2", 2" Groove
  • 1-1/2", 2" NPT x Groove


Schedule 10 Fabricated Steel Riser with Red Powder Coated Finish:

  • 2-1/2", 3", 4", 6", 8" Groove
  • The AGF Manufacturing Inc. Model 8000 Commercial RiserPACK® is a compact prepackaged economical riser assembly designed for NFPA 13 wet fire sprinkler systems.
  • The Model 8000 Commercial RiserPACK® utilizes the appropriate sized UL Listed/FM Approved patented AGF Model 2500 TESTanDRAIN® valves designed to comply with the NFPA 13 requirement regarding providing sight glasses for verification while testing through a properly sized test orifice. The Model 8000 Commercial Riser-PACK® is available with 3/8", 7/16", ½", 17/32", 5/8" (ELO), ¾" (ESFR), and K25 orifices to meet K-Factors of 2.8 to 25.
  • The UL Listed, made and machined in the U.S.A., cast bronze 1¼", 1½" and 2" RiserPACK®s are available with male threaded, grooved, and threaded x grooved ends and are rated at 300 PSI; castings are lettered on both sides allowing right or left side draining, horizontal or vertical installation. The Schedule 40 fabricated steel body with 3mil powder coated red finish 2½", 3", 4", 6", and 8" RiserPACK® is available with grooved ends and is rated at 300 PSI.
  • All RiserPACK®s are assembled with UL Listed/FM Approved AGF Model 7500 300 PSI Pressure Gauge, Model 7600 ¼" 3-way Globe Valve, and either a 1" NPT threaded or saddle mount water flow switch as required by NFPA 13.
  • The Model 8000 Commercial RiserPACK® through the Model 2500 TESTanDRAIN® valves offer a unique design benefit that allows system access through the valve for system integrity testing and/or installation of the optional relief valve trim kit (Model 8011) without system draining.
  • 1¼", 1½", an 2" RiserPACK®s utilize a 1" FNPT M2500 and are available with orifice sizes of 3/8" to 5/8" (ELO); 2½" and 3" RiserPACK®s utilize a 1¼" FNPT M2500 or 2511 and are available with orifice sizes of 3/8" to ¾" (ESFR); and 4" and 6" RiserPACK®s utilize a 2" Grooved M2500 is available with orifice sizes of 3/8" to K-25.


Made in USA

規格
  • 2.1 SPRINKLER SPECIALTY PIPE FITTINGS - Flow Detection and Test Assemblies:

    Product:  Commercial Model M8000. Includes a flow switch, TESTanDRAIN Model 2500, Model 7600 3-way Globe Valve, and a M7500 Pressure Gauge.

    ** NOTE TO SPECIFIER **  Delete riser model not required.

    1. Riser Model:  Pre-Assembled TESTanDRAIN Riser 1-1/4, 1-1/2. and 2 inches (32 mm, 38 mm, 51 mm):
      1. One-piece bronze casting, lettered on both sides allowing right or left side draining, horizontal or vertical installation.
      2. Inlet and Outlet (Cast bronze): ** NOTE TO SPECIFIER **  Delete inlet and outlet size not required.
        1. Inlet and Outlet:  Threaded.
        2. Inlet and Outlet:  Grooved 1-1/2 to 2 inches (38 mm to 51 mm).
        3. Inlet and Outlet:  Threaded and Grooved 1-1/2 to 2 inches (38 mm to 51 mm).
      3. Standard: UL's "Product iQ" listing, or "Approval Guide," published by FM Global, listing. NFPA 13.
      4. Pressure Rating: 300 psig (2070 kPa).
      5. Size: Same as connected piping.
    2. Riser Model: Pre-Assembled TESTanDRAIN Riser 2-1/2, 3, 4, 6, and 8 inch:
      1. Schedule 10 fabricated steel body with 3mil powder-coated red finish.
      2. Inlet and Outlet (Schedule 40 steel).
        1. Inlet and Outlet: Grooved 2-1/2, 3, 4, 6, and 8 inches (64 mm, 76 mm, 102 mm, 152 mm) Models.
      3. Standard: UL's "Product iQ" listing, or "Approval Guide," published by FM Global, listing. NFPA 13.
      4. Pressure Rating: 300 psig (2070 kPa).
      5. Size: Same as connected piping.
    3. Valve Model 2500 TESTanDRAIN valve 1-1/4, 1-1/2, and 2 inch Models:** NOTE TO SPECIFIER ** Delete valve model not required.
      1. 1 inch (25 mm) FNPT. ** NOTE TO SPECIFIER ** Delete orifice size not required.
        1. Test Orifice Size: Nominal 2.8K (3/8 inch), as required by NFPA 13, latest edition.
        2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
        3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
        4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
        5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
    4. Valve Model 2500 TESTanDRAIN valve 2-1/2 and 3 inches Models:
      1. 1 inch (25 mm) FNPT. ** NOTE TO SPECIFIER ** Delete orifice size not required.
      2. Test Orifice Size: Nominal 2.8K (3/8 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      7. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      8. Test Orifice Size: Nominal K25.2, as required by NFPA 13, latest edition.
    5. Valve Model 2500 TESTanDRAIN valve 4, 6, and 8 inches Models:
      1. 2 inches (51 mm) Grooved. ** NOTE TO SPECIFIER ** Delete orifice size not required.
      2. Test Orifice Size: Nominal 2.8K (3/8 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      7. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      8. Test Orifice Size: Nominal K25.2, as required by NFPA 13, latest edition.
      9. Water flow alarm switch.
      10. Pressure Gauge: AGF Model 7500.
      11. 1/4 inch (6 mm), 3-way globe valve: AGF Model 7600.
技術規格
  • 唯一參考agf-model-8000com
  • 產品系列AGF Fire Sprinkler Products
  • 產品組合RiserPACK®
  • 類型对象(单个对象)
  • 發佈日期2019-10-18
  • 版本號1
相關
  • 主材料Bronze
  • 次要材料碳钢
  • 設計國家/地區美國
  • 製造國家/地區美國
分類
  • BIMobject 類別消防产品 - 洒水系统
  • IFC 分類阀门
  • UNSPSC 名稱Valves
  • UNSPSC 代碼401416
  • Uniclass 2015 代碼Pr_65_54
  • Uniclass 2015 說明Valve products
  • CSI MasterFormat 2014 代碼23 09 13.33
  • CSI MasterFormat 2014 標題Control Valves
  • OmniClass 編號23-27 31 00
  • OmniClass 標題Valves

發售地區

亚洲 欧洲 非洲 南美洲 大洋洲 北美
不丹
丹麥
中非共和國
厄瓜多爾
巴布亞新畿內亞
伯利茲
中國
俄羅斯
乍得
哥倫比亞
所羅門群島
加拿大
也門
保加利亞
利比亞
圭亞那
斐濟
危地馬拉
亞美尼亞
克羅地亞
利比里亞
委內瑞拉
新喀里多尼亞
古巴
以色列
冰島
剛果
巴拉圭
新西蘭
哥斯達黎加
伊拉克
匈牙利
剛果民主共和國
巴西
東帝汶
多米尼加共和國
伊朗
北馬其頓
加納
智利
澳洲
尼加拉瓜
北韓
塞浦路斯
加蓬
法屬圭亞那
瓦努阿圖
巴哈馬
南韓
塞爾維亞
南蘇丹
烏拉圭
巴拿馬
卡塔爾
奧地利
南非
玻利維亞
格陵蘭島
印尼
希臘
博茨瓦納
福克蘭群島(即馬爾維納斯群島)
波多黎各
印度
德國
厄立特里亞
秘魯
洪都拉斯
台灣
意大利
吉布提
蘇里南
海地
吉爾吉斯斯坦
愛沙尼亞
喀麥隆
阿根廷
牙買加
哈薩克斯坦
愛爾蘭
坦桑尼亞
美國
土庫曼斯坦
拉脫維亞
埃及
薩爾瓦多
土耳其
挪威
埃塞俄比亞
墨西哥
塔吉克斯坦
捷克共和國
塞內加爾
孟加拉國
摩爾多瓦
塞拉利昂
尼泊爾
斯洛伐克
多哥
巴勒斯坦
斯洛文尼亞
安哥拉
巴基斯坦
斯瓦爾巴特群島
尼日利亞
敘利亞
比利時
尼日爾
斯里蘭卡
法國
岡比亞
日本
波斯尼亞 黑塞哥維那
布基納法索
柬埔寨
波蘭
布隆迪
格魯吉亞
烏克蘭
幾內亞
沙地阿拉伯
瑞典
幾內亞比索
泰國
瑞士
摩洛哥
烏茲別克斯坦
白俄羅斯
斯威士蘭
科威特
盧森堡
毛里塔尼亞
約旦
立陶宛
津巴布韋
緬甸
羅馬尼亞
烏干達
老撾
芬蘭
盧旺達
菲律賓
英國
科特迪瓦
蒙古
荷蘭
突尼斯
越南
葡萄牙
納米比亞
阿塞拜疆
西班牙
索馬里
阿富汗
阿爾巴尼亞
肯尼亞
阿拉伯聯合酋長國
黑山
莫桑比克
阿曼
萊索托
馬來西亞
蘇丹
黎巴嫩
西撒哈拉
貝寧
贊比亞
赤道幾內亞
阿爾及利亞
馬拉維
馬達加斯加島
馬里