Intelli-Balance® 100 FV-10VEC2 COLD CLIMATE 50-60-70-80-90-100 CFM, Ceiling or Wall Mount ERV
Tightly built homes and buildings utilizing exhaust only fans can create negative pressure. Intelli-Balance 100 solves this by supplying air to replace exhausted air, helping to balance air pressure within the home. Intelli-Balance 100 ERV uses four integrated dual 4” or 6” round duct adaptors – two to exhaust stale air and two to supply fresh air. Its low, continuous run helps remove moist, stale air and replace it with fresh air. Intelli-Balance 100 can be ceiling or wall mounted, does not require connection to the Central HVAC or the addition of a condensation line. This allows it to be installed in many places throughout the home to meet IAQ, health and comfort needs.
Intelli-Balance™ 100 is ideal for single family homes and multi-family units. It is a customizable, high performance, high efficiency Energy Recovery Ventilator (ERV) that’s designed to help you meet ASHRAE 62.2 requirements. This unique and cost effective Cold Climate ERV was engineered for total versatility and installation flexibility, in a cold climate zone.
DC Motor Technology - The Best Performing, Most Energy Efficient Motor Available
Intelli-Balance 100 uses two (2) DC brushless motors with built-in SmartFlow™ technology. When the ERV senses static pressure, its speed is automatically increased to ensure optimal CFM output; regardless of a complicated duct run. This feature provides peace of mind, as the installer doesn’t have to worry about compromising the ERV’s performance. Both DC motors are rated for continuous run and are totally enclosed to ensure long-life and continuous quiet operation. Each motor also comes equipped with a thermal cutoff fuse.
Multi-Speed Selector
Intelli-Balance®100 includes a built-in Multi-Speed selector that provides the uniqueability to select your required supply (50-60-70-80-90-100 CFM) and exhaust airflow(50-60-70-80-90-100 CFM), with the simple turn of a dial. This truly customizable airflow capability allows you to create balanced, positive or negative pressure within the home.
ASHRAE 62.2 TIMING FUNCTION
The adjustable Minutes Per Hour (Min/Hr) timer allows the user to set the number of minutes per hour the ERV should run. This gives scalability of air flow relative to property size; from the smallest multi-family to larger single family applications.This ensures consistent and controlled ventilation throughout the day for compliance with ASHRAE 62.2. Factory default setting is 60 Min/Hr.
Operation in Extreme Temperatures
FV-10VEC2 (Cold Climate Model): Recommended for areas where temperatures can drop as low as -22°F (-30°C). When the outdoor temperature is < -22°F (-30°C), the defrost cycle is initiated and the product will stop operating for 47 minutes, then operate in heat exchange mode for 4 minutes in order to sample the outdoor temperature. It then operates in circulation mode for 9 minutes in order to defrost (exhaust and supply air are 50 CFM). Defrost cycle overrides the ASHRAE 62.2 timing function.
Exchange Capillary Core
Indoor and outdoor air pass through Panasonic’s patented capillary core designed to transfer heat and moisture. This process tempers supply air while transferring moisture. The core’s high latent energy (moisture) transfer makes Intelli-Balance 100 ideal for use in most climate zones, as it helps expel moisture during incidences of high relative humidity (RH) and helps return moisture back inside during the winter for a healthier, more comfortable living environment.
Filters and Maintenance
Intelli-Balance®100 has two filters that clean the exhaust and supply air before passing through the ERV core, extending the life of the core. A hinged access panel allows for quick and easy product maintenance and filter checks. Convenient light indicator and unobtrusive alarm signal on the access panel will help inform the homeowner when it’s time to check and clean the filters. Both filters should be vacuumed with a soft brush attachment every 2-3 months or as needed, and the supply air filter should be inspected every 90 days and replaced every 6 months to maintain the ERV’s peak performance.
ENERGY STAR® Certified for Energy Savings*
Panasonic Energy Recovery Ventilators(ERVs) are ENERGY STAR® certified where guidelines exist. ENERGY STAR® ERVs meet strict parameters set by the Environmental Protection Agency (EPA). Model FV-10VEC2 meets strict energy efficiency guidelines set by Natural Resources Canada and is ENERGY STAR® certified for the Canadian market only.
PRODUCT DETAILS
Intelli-Balance®100 is ideal for single family homes and multi-family units. It is a customizable, high performance, high efficiency Energy Recovery Ventilator (ERV) that’s designed to help you meet ASHRAE 62.2 requirements. This unique and cost effective Cold Climate ERV was engineered for total versatility and installation flexibility, in a cold climate zone. Now with Boost function, which can move the fan speed to high when activated.
KEY FEATURES
發售地區
| 北美 |
|---|
伯利茲 |
加拿大 |
千里達和多巴哥 |
危地馬拉 |
古巴 |
哥斯達黎加 |
多米尼克 |
多米尼加共和國 |
安圭拉 |
安提瓜和巴布達 |
尼加拉瓜 |
巴哈馬 |
巴巴多斯 |
巴拿馬 |
庫拉索 |
格林納達 |
格陵蘭島 |
法屬聖馬丁 |
波多黎各 |
洪都拉斯 |
海地 |
牙買加 |
特克斯和凱科斯群島 |
瓜德羅普 |
百慕達 |
美國 |
美屬維爾京群島 |
聖基茨和尼維斯 |
聖巴泰勒米 |
聖文森與格瑞那丁 |
聖皮埃爾和密克隆群島 |
聖盧西亞 |
英屬維爾京群島 |
荷屬聖馬丁 |
荷蘭加勒比區 |
蒙塞拉特島 |
薩爾瓦多 |
開曼群島 |
阿魯巴 |
馬提尼克 |
墨西哥 |