發佈您的產品
Rockfon MediCare Block
Rockfon MediCare Block
    Rockfon

    Rockfon MediCare Block

    • Specifically designed for use in high-risk, pressurised healthcare environments where high cleanability is required such as emergency rooms, washing facilities and intensive care (compliant with HBN 00-10, TDM 4032:0.6 and HTM 60).
    • For use in operating theatres, seek client approval.
    • Does not contribute to the growth of MRSA, high-rated Bacteriological Class B1 and Clean Room Classification ISO Class 2.
    • Very good cleanability properties, chemical resistance classification ‘Excellent’.
    規格
    • Sound absorption αw: 0.90 (Class A)
      Reaction To Fire B-s1,d0
      Light Reflection 74%
      Humidity and Sag Resistance Up to 100% RH.
      No visible deflection in high humidity
      Surface Durability The high performance inert film of Rockfon MediCare Block provides enhanced durability and water-repellence.
      The film contains DMAc (CAS 127-19-5) in a concentration ≥ 0.1% and < 1% by weight.
      Cleaning Vacuum, Damp cloth, Dry steam cleaning (daily), Resistant to disinfection using Hydrogen Peroxide Vapour, with no impact on aeration time, Chemical resistance: Tested according to ISO 2812-1 (“Determination of resistance to liquids - Part 1: Immersion in liquids other than water”) and classification in accordance with VDI 2083 Part 17. Results are classified as ‘Excellent’ with the following detergents and disinfectants (daily disinfection): – Formalin (37%) – Ammonia (25%) – Hydrogen peroxide (30%) – Sulphuric acid (5%) – Phosphoric acid (30%) – Peracetic acid (15%) – Hydrochloric acid (5%) – Isopropanol (100%) – Sodium hydroxide (5%) – Sodium hypochlorite (15%)
      Clean Room Classification ISO Class 2
      Air Pressure Suitable in areas where differential pressure is required.
      When used in combination with closed neoprene foam tape and:
      -HDC 2 for the 25 mm tile; or
      -HDC 7 for the 40 mm tile,
      the air leakage rate of less than 0.5m³/h/ m²/Pa under a pressure range of 5 to 40 Pa is achieved.
      The amount of hold down clips (HDC) depends on the tile dimensions and the room size/shape.
      For more information please contact customer service.
    技術規格
    • 唯一參考rockfon-medicare-block
    • 產品系列Suspended Ceilings
    • 產品組合Medicare
    • 類型对象(单个对象)
    • 發佈日期2017-12-14
    • 版本號1
    相關
    • 主材料岩棉
    • 次要材料钢
    • 設計國家/地區丹麥
    分類
    • BIMobject 類別建筑 - 天花板
    • IFC 分類天花板
    • ETIM 代碼EG000041
    • ETIM 名稱Consumer electronics
    • UNSPSC 名稱Ceiling panels
    • UNSPSC 代碼30161602
    • Uniclass 2015 代碼Ss_30_25_22_90
    • Uniclass 2015 說明Unit/ modular suspended ceiling systems
    • CSI MasterFormat 2014 代碼09 51 00
    • CSI MasterFormat 2014 標題Acoustical Ceilings
    • OmniClass 編號23-15 13 21
    • OmniClass 標題Ceiling Panels

    發售地區

    欧洲
    丹麥
    保加利亞
    克羅地亞
    冰島
    列支敦士登
    匈牙利
    北馬其頓
    塞浦路斯
    塞爾維亞
    奧地利
    奧蘭
    安道爾
    希臘
    德國
    意大利
    愛沙尼亞
    愛爾蘭
    拉脫維亞
    挪威
    捷克共和國
    摩爾多瓦
    摩納哥
    斯洛伐克
    斯洛文尼亞
    斯瓦爾巴特群島
    根息
    梵蒂岡
    比利時
    法國
    法羅群島
    波斯尼亞 黑塞哥維那
    波蘭
    澤西島
    烏克蘭
    瑞典
    瑞士
    白俄羅斯
    盧森堡
    直布羅陀
    立陶宛
    羅馬尼亞
    聖馬力諾
    芬蘭
    英國
    荷蘭
    葡萄牙
    西班牙
    阿爾巴尼亞
    馬恩島
    馬耳他
    黑山