Single Stage Even Heat Infrared Heater, Model LX

Single Stage Even Heat Infrared Heater, Model LX

Model LX Ultra-rugged enclosed burner design further enhances all of the great features of the LA for hard service applications. Post-purge function and optional 10-year tube warranty.

  • LX model features a totally enclosed construction with post purge
  • End to end radiant output variance less than 15%
  • Ideal for animal confinement applications, low ceilings, hallways, service counters
  • 40,000 BTU/H, 30 or 40 feet long
  • 60,000 BTU/H, 30, 40 or 50 feet long
  • 80,000 BTU/H, 40, 50 or 60 feet long
  • 100,000 BTU/h, 50 feet
  • Separate controls compartment isolates electrical components from air stream
  • Self diagnostic ignition module
  • 100% Efficient parabolic aluminum reflector
  • Vented or unvented
  • Natural Gas or LPG
  • Configurations: U, L, horizontal to 45
  • Jet stream burner – improved heat distribution, better combustion
  • Heavy duty couplings – no leaks, cannot be over tightened
  • Three year warranty on all components
  • Ten year warranty on aluminized heat exchanger with post purge feature
  • Direct spark ignition
  • Operating status lights
規格
  • Low intensity, low clearance, even heat single-stage infrared tube heaters. Heavy-duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents within the range of 40 MBH to 100 MBH. Designed for low clearance, even heat applications. All L Series units include our patented design, which provides unequalled even heat distribution with end to end output variance of less than 15%. Baffles required as per manufacturer’s instructions. Assemblies shall be CSA approved low-intensity heater to the latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a positive pressure burner system where exhaust gases and other products of combustion are not routed through the blower.   The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz.

    Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks with the burner operating. Reflector shall have a minimum 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with fewer than 10 surfaces will not be allowed as they allow energy to bounce back to the main heat exchanger tubing. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, type 1 aluminized steel tubing and be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    Independent testing to show even distribution of hot gases along the complete length of the emitter tube with a minimum variance of 15%Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with an alternate system.Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).

技術規格
  • 唯一參考lx
  • 產品系列Single Stage Infrared Heaters
  • 產品組合Low Clearance - Series L
  • 類型对象(单个对象)
  • 發佈日期2021-02-16
  • 版本號1
相關
  • 主材料钢
  • 次要材料铝
  • 設計國家/地區加拿大
  • 製造國家/地區加拿大
分類
  • BIMobject 類別暖通空调 - 加热装置
  • UNSPSC 名稱Tubular heaters
  • UNSPSC 代碼40101822
  • Uniclass 2015 代碼Pr_70_60_36_72
  • Uniclass 2015 說明Radiant tube heaters
  • CSI MasterFormat 2014 代碼23 55 23
  • CSI MasterFormat 2014 標題Gas-Fired Radiant Heaters
  • OmniClass 編號23-33 15 17 13
  • OmniClass 標題Fuel Fired HVAC Radiant Heaters
  • CSI UniFormat II 代碼D30
  • CSI UniFormat II 標題HVAC

發售地區

北美
伯利茲
加拿大
千里達和多巴哥
危地馬拉
古巴
哥斯達黎加
多米尼克
多米尼加共和國
安圭拉
安提瓜和巴布達
尼加拉瓜
巴哈馬
巴巴多斯
巴拿馬
庫拉索
格林納達
格陵蘭島
法屬聖馬丁
波多黎各
洪都拉斯
海地
牙買加
特克斯和凱科斯群島
瓜德羅普
百慕達
美國
美屬維爾京群島
聖基茨和尼維斯
聖巴泰勒米
聖文森與格瑞那丁
聖皮埃爾和密克隆群島
聖盧西亞
英屬維爾京群島
荷屬聖馬丁
荷蘭加勒比區
蒙塞拉特島
薩爾瓦多
開曼群島
阿魯巴
馬提尼克
墨西哥