Negative Pressure Infrared Heater - Series TVX

Negative Pressure Infrared Heater - Series TVX

The Series TVX negative pressure multi-burner system was designed to use two or more radiant tube heaters in a variety of applications, these systems offer significant operating benefits that are not easily obtainable with traditional infrared tube heaters.

Flexible layouts (Herringbone, Fork, "T", Flag, etc.) can be adapted to fit a wide range of applications heating and space requirements. Available input rates 60 / 80 / 100 / 125 / 150 / 175 / 205 / 220 MBH all featuring a two-stage configuration.

Features

  •   Input rates 60 to 220 MBH
  •   Lengths –  from 20’ to 60’
  •   Two-stage for comfort control 
  •   100% efficient reflector 
  •   Sealed burner box 
  •   3 try ignition 
  •   Integral safety switch  
  •   Simple controls 
  •   Multi-zone capability
  •   State-of-the-art pump with ECM motor
  •   Up to 525 MBH on single vent penetration
  •   Easy setup and commissioning 
  •   Standard gas flex and shut off valve are used
  •   Installation benefits – fewer vents needed
  •   Optional Equipment:
    • Elbows, Utube, outside air kit
    • Side shields, deco grille, bottom shield
規格
  • Low Intensity, Two-Stage, Negative pressure Infrared Tube Heating System - Heavy duty industrial/commercial infrared heating system, featuring the best overall radiant performance in the industry. Firing rates as called for in the Contract documents within the range of 60/45 MBH to 220/165 MBH. 100% efficient reflector design with minimum 65% radiant factor as determined by independent lab testing to EN416 Standard. Baffles required as per manufacturer’s instructions. Product shall be Custom-designed, Negative Pressure, Low-Intensity Infrared Heating System: Model TVX as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks to be conducted with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish design with emitter tubes fully recessed within reflector. Reflectors shall have a minimum of 10 reflective surfaces. Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024-inch thickness aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall always extend below the lowest position of the tubing and include standard end caps. Reflector end caps: Shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4-inch (102 mm) diameter, minimum 16-gauge thickness, hot rolled steel, heat-treated type 1 aluminized steel or type 409 stainless steel materials. Heat Uniformity: Burner shall distribute hot gases along the length of the emitter tubes. Combustion Tube shall be 4 inches (102 mm) diameter, 16-gauge, heat-treated type 1 aluminized steel tubing for all firing rates. Hot rolled steel shall not be allowed. The combustion tube shall incorporate a continuously welded, 11-gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16-gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands. Exhaust pump motor shall be totally enclosed requiring no oiling and shall be equipped with overcurrent protection. It shall be one of A. For systems up to 250,000 BTU/Hr - Permanent Split Capacitor (PSC) type, Electrical supply: 120V, 60Hz, 1 PH, 1 A.B. For systems up to 525,000 BTU/Hr - Electrically Commutated Motor (ECM) Electrical supply 120V, 60Hz, 1 PH, 5 A. This product was specified based on best practice design to meet the specific engineering design criteria for this project. No Substitution Permitted. Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:- Independent lab testing to EN416 standard dated no later than 6 months from date of submission showing minimum 65% radiant factor.- Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.- Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model - Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).

技術規格
  • 唯一參考tvx
  • 產品系列Negative Pressure Systems
  • 產品組合Series TVX
  • 類型对象(单个对象)
  • 發佈日期2021-02-16
  • 版本號1
相關
  • 主材料钢
  • 次要材料铝
  • 設計國家/地區加拿大
  • 製造國家/地區加拿大
分類
  • BIMobject 類別暖通空调 - 加热装置
  • IFC 分類小型供暖器
  • UNSPSC 名稱Space heaters
  • UNSPSC 代碼40101819
  • Uniclass 2015 代碼Pr_70_60_36_72
  • Uniclass 2015 說明Radiant tube heaters
  • CSI MasterFormat 2014 代碼23 55 23
  • CSI MasterFormat 2014 標題Gas-Fired Radiant Heaters
  • OmniClass 編號23-33 15 17 13
  • OmniClass 標題Fuel Fired HVAC Radiant Heaters
  • CSI UniFormat II 代碼D30
  • CSI UniFormat II 標題HVAC

發售地區

欧洲 北美 亚洲
丹麥
伯利茲
不丹
俄羅斯
加拿大
中國
保加利亞
千里達和多巴哥
亞美尼亞
克羅地亞
危地馬拉
北韓
冰島
古巴
南韓
列支敦士登
哥斯達黎加
印尼
匈牙利
多米尼克
印度
北馬其頓
多米尼加共和國
台灣
塞浦路斯
安圭拉
吉爾吉斯斯坦
塞爾維亞
安提瓜和巴布達
哈薩克斯坦
奧地利
尼加拉瓜
土庫曼斯坦
奧蘭
巴哈馬
塔吉克斯坦
安道爾
巴巴多斯
孟加拉國
希臘
巴拿馬
尼泊爾
德國
庫拉索
巴基斯坦
意大利
格林納達
斯里蘭卡
愛沙尼亞
格陵蘭島
新加坡
愛爾蘭
法屬聖馬丁
日本
拉脫維亞
波多黎各
柬埔寨
挪威
洪都拉斯
格魯吉亞
捷克共和國
海地
汶萊
摩爾多瓦
牙買加
泰國
摩納哥
特克斯和凱科斯群島
澳門
斯洛伐克
瓜德羅普
烏茲別克斯坦
斯洛文尼亞
百慕達
科科斯(基林)群島
斯瓦爾巴特群島
美國
緬甸
根息
美屬維爾京群島
老撾
梵蒂岡
聖基茨和尼維斯
聖誕島
比利時
聖巴泰勒米
英屬印度洋領地
法國
聖文森與格瑞那丁
菲律賓
法羅群島
聖皮埃爾和密克隆群島
蒙古
波斯尼亞 黑塞哥維那
聖盧西亞
越南
波蘭
英屬維爾京群島
阿塞拜疆
澤西島
荷屬聖馬丁
香港
烏克蘭
荷蘭加勒比區
馬來西亞
瑞典
蒙塞拉特島
馬爾代夫
瑞士
薩爾瓦多
白俄羅斯
開曼群島
盧森堡
阿魯巴
直布羅陀
馬提尼克
立陶宛
墨西哥
羅馬尼亞
聖馬力諾
芬蘭
英國
荷蘭
葡萄牙
西班牙
阿爾巴尼亞
馬恩島
馬耳他
黑山