Infrared Vacuum System, Model VS-VH

The Premier Vacuum Series takes full advantage of the performance synergies that only an engineered system can provide. Unlike other “systems” which merely connect multiple unitary style heaters, this maximum design flexibility ensures that all the performance and energy savings requirements of the application can be realized.

Designs are further enhanced by a full complement of additional features, including diverse tubing materials, reflector shielding configurations, multiple vacuum pump sizes, and advanced control options.

  • In-series burners provide even heat distribution dramatically increasing personal comfort.
  • Can be designed as a condensing system maximizing fuel efficiency and savings.
  • Balanced air and fuel flow ensures complete and efficient combustion.
  • Position tuned burners optimize efficiency while ensuring a more even heat output with patented metering technology.
  • Reliable and safe operation with zero regulator incorporated into the burner
    Minimal vent penetrations up to 600,000 BTUh/system.
  • 100% efficient SRP reflector ensures all the infrared is directed where it is needed
規格
  • Low-Intensity infrared Premier Vacuum System VS or VS-VH high efficiency condensing or mid-efficiency non-condensing featuring positioned tuned in-line burners to guarantee the best system efficiency in the industry. Firing rates shall be within the range of 20 MBH to 250 MBH (Model VS shall be 80,000 BTU/HR to 250,000 BTU/HR and Model VS-VH Shall be 20,000 BTU/HR to 120,000 BTU/HR). Burners shall be position-tuned and shall be factory designed to operate in a specific in-line position in the radiant branch to ensure equal firing rates for each burner in the branch. Except for the first burner, subsequent burners in a leg shall have firing rates within +/- 2% of each other. Radiant branches shall contain up to 4 burners in-line on a single branch and must be capable of modulating from 60% to 100% of normal firing rates. Minimum end vent flow rates based on design may not exceed the design provided. End vent flow rates of 200% or more will not be permitted. Assemblies shall be CSA approved to the latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a negative pressure burner system where exhaust gases and other products of combustion are routed through the blower.   The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.0 inches W.C. (propane – VS Burners only) and draw no more than 0.2 Amp at 120VAC, 60Hz. Burner head and mounting body shall be cast iron and burner controls shall allow service and diagnostic control checks with the burner operating. Reflector shall have a minimum 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with fewer than 10 surfaces will not be allowed as they allow energy to bounce back to the main heat exchanger tubing. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing and shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall allow fastening of the burner via dual U clamps to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project. 

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Professional Engineer design showing end vent airflow entry rate as equal as or less than design. 
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with an alternate system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model.
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
技術規格
  • 唯一參考vs-vh
  • 產品系列Premier Vacuum Series
  • 產品組合Premier VS-VH
  • 類型对象(单个对象)
  • 發佈日期2021-02-16
  • 版本號1
相關
  • 主材料钢
  • 次要材料铝
  • 設計國家/地區加拿大
  • 製造國家/地區加拿大
分類
  • BIMobject 類別暖通空调 - 加热装置
  • IFC 分類小型供暖器
  • UNSPSC 名稱Space heaters
  • UNSPSC 代碼40101819
  • Uniclass 2015 代碼Pr_70_60_36_72
  • Uniclass 2015 說明Radiant tube heaters
  • CSI MasterFormat 2014 代碼23 55 23
  • CSI MasterFormat 2014 標題Gas-Fired Radiant Heaters
  • OmniClass 編號23-33 15 17 13
  • OmniClass 標題Fuel Fired HVAC Radiant Heaters
  • CSI UniFormat II 代碼D30
  • CSI UniFormat II 標題HVAC

發售地區

北美
伯利茲
加拿大
千里達和多巴哥
危地馬拉
古巴
哥斯達黎加
多米尼克
多米尼加共和國
安圭拉
安提瓜和巴布達
尼加拉瓜
巴哈馬
巴巴多斯
巴拿馬
庫拉索
格林納達
格陵蘭島
法屬聖馬丁
波多黎各
洪都拉斯
海地
牙買加
特克斯和凱科斯群島
瓜德羅普
百慕達
美國
美屬維爾京群島
聖基茨和尼維斯
聖巴泰勒米
聖文森與格瑞那丁
聖皮埃爾和密克隆群島
聖盧西亞
英屬維爾京群島
荷屬聖馬丁
荷蘭加勒比區
蒙塞拉特島
薩爾瓦多
開曼群島
阿魯巴
馬提尼克
墨西哥