60 to 120 minute fire resistive, hurricane rated aluminum clad framing system with Florida Product Approval Numbers:
Fixed Window/Wall: FL16382
Singe and Pair Doors: FL 16888
Meets to the following standards:
ASTM E-119/NFPA251/UL263 up to 2 hours with hose stream for Fire Resistance
ASTM E283 for Air Infiltration Leakage
ASTM E331/ASTM 547 for Water Penetration
ASTM E330/TAS 202 for Uniform Static Air Pressure
FBC 1626.2 (TAS 201 and 203) for Large Missile Impact and Cyclic Wind Loading
AAMA 1302.5-76 and 1303.5-76 for Forced Entry (for doors)
ASTM E1300 for Determining Load Resistance of Glass in Buildings
Complies with High Velocity Hurricane Zone (HVHZ) testing requirements.
Maximum design loads up to +/- 80 PSF.
Glazing make-up is SuperLite II-XL insulated with 9/16" DuPont Sentry Plus Laminated Glass
Dow Corning 995 to be used as the perimeter sealant
Enrolled in Architectural Testing Inc.’s Quality Assurance Program
Offered in standard and custom finishes including high performance fluoropolymer finishes by PPG, clear anodized, bronze anodized, black anodized, Decoral®, ornamental metal, and more.
Fire Resistive Hurricane Doors
60 and 90 minute fire resistive, hurricane rated aluminum clad singe and pair door.
5" vertical stile, 5" head and 10" bottom rail (bottom rail can be modified with AHJ approval).
Door is 4" – 5" deep.
52 ¼" maximum single door width.
104 ½" maximum pair door width.
105 ¼" maximum door height.
Available profiles:
5"
Fire Resistive Hurricane Wall/Window
60 to 120 minute fire resistive, hurricane rated aluminum clad wall/window.
144” maximum wall height.
40" maximum wall width before vertical mullion is introduced.