发布您的产品
IT Smoke Exhaust
IT Smoke Exhaust
IT Smoke Exhaust
IT Smoke Exhaust

    IT Smoke Exhaust

    Single Installation of a Smoke Exhaust Window

    Smoke ventilation roof window for sloped roofs is centre-pivoted, mains-powered and operated via the control system for smoke ventilation. The solution is available with and without wind deflector.

    Installation type - Object Type Description

    Speed up your early design process with pre-defined VELUX installation solutions.

    Use Installation Types to quickly explore daylight concepts, roof layouts, window sizes, and roof window placements without committing to detailed product specifications too early in the project.

    These lightweight BIM objects are specifically developed for concept and schematic design stages. Geometry and product information are intentionally simplified, allowing you to focus on space, daylight, proportions, and overall design intent while maintaining maximum flexibility for later project development.

    Switch between different roof window sizes and configurations to identify the solution that best fits your design. Once the project requirements become clearer, refine the selected Installation Type into specific VELUX roof windows with detailed performance data, operation type, glazing, finishes, blinds, shutters, and accessories.

    When your project requires detailed geometry and specification-ready product information, continue the design process using CoBIM and the VELUX Revit Add-in.

    Why Smoke Exhaust?

    Planning the smoke exhaust strategy is an important part of the building design process and should be considered early in the project. As smoke naturally rises, the roof is often the most effective location for natural smoke and heat exhaust. Integrating this function into a roof window allows one installation to fulfil multiple purposes throughout the building's lifecycle.

    A VELUX smoke exhaust roof window combines three key functions in a single solution:

    - Brings natural daylight into the space
    - Provides daily natural ventilation for occupant comfort
    - Acts as a certified smoke exhaust opening in the event of a fire

    The complete system includes the smoke exhaust roof window together with a dedicated control system, including components such as a control panel, manual break-glass call point(s), smoke detector(s), rain sensor and a comfort switch for everyday operation. This enables the window to function as both a daily comfort solution and an emergency smoke exhaust system when required.

    For projects where a higher smoke exhaust capacity is required, the window can be equipped with an aerodynamic wind deflector. The deflector can more than double the aerodynamic free area (Aa) compared to a standard opening, significantly increasing smoke extraction performance without requiring a larger roof opening. This provides a substantial design advantage, helping meet performance requirements while optimising roof space and reducing the need for larger or additional smoke exhaust openings.


    Key Benefits

    - Certified smoke exhaust opening for enhanced fire safety
    - Provides natural ventilation for everyday comfort
    - Exceptional smoke exhaust performance with an optional aerodynamic wind deflector, twice the aerodynamic free area (Aa)
    - Remote operation for convenient everyday ventilation
    - Combines daylight, ventilation and smoke exhaust in a single roof opening
    - Consistent architectural appearance with other VELUX roof windows
    - Factory-engineered system with compatible components
    - Consistent detailing and proven weather performance

    Window
    Code
    Width
    in mm
    Height
    in mm
    Effective
    Daylight Area in m2
    MK04 780 978 0.47
    MK06 780 1178 0.59
    MK08 780 1398 0.72
    PK06 940 1178 0.75
    PK08 940 1398 0.92
    SK06 1140 1178 0.95
    SK08 1140 1398 1.16
    UK04 1340 978 0.91
    UK08 1340 1398 1.40


    Aerodynamic smoke 
    ventilation area 
    with KFD (Aa)
    Aerodynamic smoke 
    ventilation area 
    without KFD (Aa)
    Geometric smoke 
    ventilation area 
    (Av)
    MK04 0.36 m² 0.19 m² 0.63 m²
    MK06 0.46 m² 0.29 m² 0.77 m²
    MK08 0.59 m² 0.43 m² 0.92 m²
    PK06 0.53 m² 0.30 m² 0.95 m²
    PK08 0.68 m² 0.46 m² 1.14 m²
    SK06 0.61 m² 0.28 m² 1.17 m²
    SK08 0.77 m² 0.44 m² 1.40 m²
    UK04 0.54 m² 0.16 m² 1.13 m²
    UK08 0.83 m² 0.38 m² 1.67 m²
    技术规格
    • 唯一参考IT-smoke-exhaust
    • 产品系列Windows
    • 产品组Installation Types
    • 类型集合(多个对象)
    • 发布日期2026-07-01
    • 版本号1
    相关
    • 主材料玻璃
    • 次要材料松木
    • 设计国家/地区丹麦
    分类
    • BIMobject 类别窗户 - 天窗
    • IFC 分类窗户
    • ETIM 代码EC003112
    • ETIM 名称Skylight
    • Uniclass 2015 代码Ss_30_30_72_73
    • Uniclass 2015 说明Roof window systems
    • CSI MasterFormat 2014 代码08 60 00
    • CSI MasterFormat 2014 标题Roof Windows and Skylights
    • OmniClass 编号23-17 13 23
    • OmniClass 标题Roof Windows

    发售地区

    欧洲
    丹麦
    乌克兰
    保加利亚
    克罗地亚
    冰岛
    列支敦士登
    匈牙利
    北马其顿
    卢森堡
    圣马力诺
    塞尔维亚
    塞浦路斯
    奥兰
    奥地利
    安道尔
    希腊
    德国
    意大利
    拉脱维亚
    挪威
    捷克共和国
    摩尔多瓦
    摩纳哥
    斯洛伐克
    斯洛文尼亚
    斯瓦尔巴特群岛
    格恩西岛
    梵蒂冈
    比利时
    法国
    法罗群岛
    波兰
    波斯尼亚 黑塞哥维那
    泽西岛
    爱尔兰
    爱沙尼亚
    瑞典
    瑞士
    直布罗陀
    立陶宛
    罗马尼亚
    芬兰
    英国
    荷兰
    葡萄牙
    西班牙
    阿尔巴尼亚
    马恩岛
    马耳他
    黑山
    Common.Footer.ValueProp.Image.AltText

    Revit 版 Design App

    只需单击一下,即可将族直接加载到您的 Revit 模型中

    获取一个更轻松地访问新对象、存储 Revit 族以及与团队协作的地方。

    • 勾选标记直接与 Revit 旁边的 BIM 对象一起工作
    • 勾选标记 2GB 云存储 - 存储您的 Revit 内容
    • 勾选标记 直接从 Revit 获取内含碳 LCA (A1-A3)