    This non-ventilated cladding system allows ZINC PLUS standing seam cladding to be installed on a continuous insulating substrate of rigid mineral wool. Non-ventilated cladding is a composite system that does not require a ventilation gap beneath the zinc. The zinc is therefore installed directly onto its substrate. This requires the use of ZINC PLUS. VMZINC’s ZINC PLUS is coated on the underside with a white protective layer of organic composition which provides resistance to abrasion caused by the expansion of the zinc at the fixing points. Installation is simplified as there is no need for ventilation inlets or outlets.

    The standing seam is aesthetic, modern, and offers uniform, low-profile joints (25 mm high with a thickness of 5 mm).

    Packaging:
    The zinc is delivered in rolls to be profiled or in preformed strips on demand.

    Surface aspects: ZINC PLUS 0,7mm and 0,8mm (available in Naturel PLUS, QUARTZ-ZINC® PLUS, ANTHRA-ZINC® PLUS, PIGMENTO® PLUS, AZENGAR® PLUS and lacquered Zinc PLUS), together with the entire product range, are classified A1 and do not contribute to fire spread. Lacquered finishes are classified A2. The cladding system achieves a fire classification of C-s3,d1 or B-s3,d1 in accordance with SBI test report 2390C WRGENT. According to the test conditions, the insulation must achieve at least a D reaction-to-fire classification.

    The use of the chosen aspect may not be suitable for certain applications in the context of very aggressive environmental constraints. It is recommended, if necessary, to consult the VM Building Solutions services for further information.

    规格
    • Application:

      New build and renovation projects, with simple or complex forms. Buildings with indoor climate classes 1, 2 and 3. Heigt of the building superior of 25m.

      Standard Dimensions:

      Effective width: 430mm and 530mm

      Tray length: The maximum panel length is 4 m on façades and between 0.5 m and 2 m on soffits.

      Fixings: Stainless steel fixed clips (with spacer) and sliding clips (with load-distribution plate), specially designed for this system and mechanically fixed with screws. Clips shall be installed at 330 mm centres

      Insulation: Rigid rock wool insulation (e.g. Rockmax Sigma by Rockwool), with a minimum fire rating of Class A2 and a maximum thickness of 160 mm when installed on a concrete substrate. The insulation has a compressive strength of at least 40 kPa at 10 per cent deformation.

      ClassDoP and environmental: Environmental certifications and sustainability schemes: HQE (France – High Environmental Quality), BREEAM (United Kingdom – BRE Environmental Assessment Method), IBU certification (Germany – Institut Bauen und Umwelt), and LEED (United States – Leadership in Energy and Environmental Design).

      Fire Resistance: Complies with requirements for:

      High-rise buildings (A2-s3,d0)
      Medium-rise buildings (B-s3,d1)
      Low-rise buildings (C-s3,d1 and D-s3,d1)

    技术规格
    • 唯一参考BE-VMZINC-Standing-seam-Warm-Facade-MINERAL-WOOL-Insulation
    • 产品系列Couverture
    • 产品组VMZINC ROOFING
    • 类型对象(单个对象)
    • 发布日期2026-10-06
    • 版本号1
    相关
    • 主材料金属
    • 次要材料隔离
    • 设计国家/地区法国
    • 制造国家/地区法国
    分类
    • BIMobject 类别建筑 - 屋顶
    • IFC 分类屋顶
    • UNSPSC 名称Roofing materials
    • UNSPSC 代码301515
    • Uniclass 2015 代码Ss_30_40_50_95
    • Uniclass 2015 说明Zinc sheet roof covering systems
    • CSI MasterFormat 2014 代码07 41 13
    • CSI MasterFormat 2014 标题Metal Roof Panels
    • OmniClass 编号23-13 39 11 11
    • OmniClass 标题Exterior Metal Roof Panels
    • CSI UniFormat II 代码B3010
    • CSI UniFormat II 标题Roof Coverings

    发售地区

    欧洲
    卢森堡
    比利时
    荷兰
    BIMobject 产品库

    Revit 版 Design App

    只需单击一下,即可将族直接加载到您的 Revit 模型中

    获取一个更轻松地访问新对象、存储 Revit 族以及与团队协作的地方。

    • 勾选标记直接与 Revit 旁边的 BIM 对象一起工作
    • 勾选标记 2GB 云存储 - 存储您的 Revit 内容
    • 勾选标记 直接从 Revit 获取内含碳 LCA (A1-A3)