Termékek közzététele
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern
    Wilkins

    975XL3N Reduced Pressure Principle Backflow Preventer, – N-Pattern

    Ideal for use where Lead-Free* valves are required. Designed for installation on potable water lines to protect against both  backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. Model 975XL3N is for applications requiring vertical flow up and vertical flow down.

    Compliance:

    • ASSE® Listed 1013
    • AWWA Compliant C511
    • CSA® Certified B64.4
    • cUPC® Listed
    • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
      Meets the requirements of NSF/ANSI/CAN 61 & 372 *(LESS THAN 0.25% WEIGHTED AVERAGE LEAD CONTENT)

    Features:

    • N-pattern configuration with lay length designed for drop-in replacement of legacy irrigation and landscape backflow installations, reducing labor, materials, and enclosure rework.
    • All-bronze body ensures durability against the elements, with a Noryl®* check body and stainless-steel fasteners to resist corrosion over time.
    • Shares body, EZSWAP® modular checks, relief valve components, and repair kits with the 975XL3 platform for simple maintenance and stocking and service efficiency.
    • Test ports located on valve’s centerline make install and testing easy
    • Interlocking connected checks allow for ¼-turn access for fast disassembly and maintenance
    • Low-cost repair kits extend the lifespan at a significantly lower cost
    • Lead Free* bronze body (0.25% max. weighted average lead content) suitable for potable and irrigation applications.
    • ASSE Listed, UPC® Listed, Meets NSF/ANSI/CAN 61 & 372 requirements; Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California; Safe Drinking Water Act Compliant
    Műszaki specifikáció
    • Egyedi azonosító975XL3N
    • TermékcsaládBackflow Preventers
    • TermékcsoportReduced Pressure Principle Assembly
    • TípusObjektum (egy termék)
    • Megjelenés dátuma2026-04-10
    • Verziószám1
    Kapcsolódó adatok
    • Tervezés helyeEgyesült Államok
    Besorolások
    • BIMobject kategóriaVízvezeték-szerelés - Szelepek

    Termék elérhetősége

    Észak-Amerika
    Anguilla
    Antigua és Barbuda
    Aruba
    Bahama-szigetek
    Barbados
    Belize
    Bermuda
    Brit Virgin-szigetek
    Caribbean Netherlands
    Costa Rica
    Curaçao
    Dominikai Közösség
    Dominikai Köztársaság
    Egyesült Államok
    El Salvador
    Grenada
    Grönland
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaica
    Kajmán-szigetek
    Kanada
    Kuba
    Martinique
    Mexikó
    Montserrat
    Nicaragua
    Panamaváros
    Puerto Rico
    Saint Kitts és Nevis
    Saint Lucia
    Saint Pierre és Miquelon
    Saint Vincent és a Grenadine-szigetek
    Saint-Barthélemy
    Saint-Martin
    Sint Maarten
    Trinidad és Tobago
    Turks- és Caicos-szigetek
    Virgin-szigetek
    Common.Footer.ValueProp.Image.AltText

    Design App a Revithez

    Töltse be a családokat közvetlenül a Revit modelljébe egyetlen kattintással

    Szerezzen egy helyet, ahol könnyebben hozzáférhet az új objektumokhoz, tárolhatja a Revit családokat és együttműködhet csapatával.

    • PipaDolgozzon közvetlenül a BIM objektumokkal a Revit mellett
    • Pipa 2 GB felhőtárhely – tárolja Revit tartalmát
    • Pipa Szerezzen be megtestesült szén-dioxid LCA-t (A1-A3) közvetlenül a Revitből