Termékek közzététele
Wilkins 375 Reduced Pressure Principle Backflow Preventer, 1/2" to 2"
Wilkins

Wilkins 375 Reduced Pressure Principle Backflow Preventer, 1/2" to 2"

Designed for installation on irrigation water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. For non-potable applications only.

Compliance:

  • ASSE® Listed 1013
  • cUPC® Listed
  • CSA® Certified B64.4
  • AWWA Compliant C511
    • Approved by the Foundation for Cross Connection Control and Hydraulic
    Research at the University of Southern California

Features:

  • EZSwap® Pressure Vessel is removable for easy access and added convenience
  • Flush Tool (FLUSH) provides easy line flushing, saving up to 15 minutes per installation
  • Durable UV resistant reinforced nylon EZSwap Pressure Vessel resists corrosion and mineral build-up to better withstand harsh conditions
  • Minimal bronze construction acts as theft deterrent
  • High pressure rating of 175 psi
  • ASSE listed 1013 and IAPMO listed
  • CSA Certified B64.4
Specifikáció
  • The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180°F and supplied with full port ball valves. The main body shall be Nylon and the seat disc elastomers shall be silicone. If installed indoors, the installation shall be supplied with an air gap adapter. For non-potable applications only. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 375.

    keywords: Backflow Preventers,Lead-Free Products,Zurn Wilkins Water Control,Government Buildings,Commercial,High Rise Buildings,Hospitality,Military,Office,Retail,Healthcare,School Systems,Educational Facilities,Universities,Power Generation,Industrial,Irrigation,Architectural/Aesthetics,Development,Civil,Transportation,Correctional/Institutional,Fire Protection,Food Service,Industrial/Processing Plant,Light Commercial,Residential Multi-Family,Residential/Light Commercial,Sports Complex/Recreational Center,Waterworks,Reduced Pressure Principle Assembly,Zurn Wilkins Backflow Preventers,Lead-Free Law Compliance,MasterSpec,Retrofit and Replacement,Water Conservation,Zurn Wilkins,,75,5

Műszaki specifikáció
  • Egyedi azonosítózurn-375sm
  • TermékcsaládBackflow Preventers
  • TermékcsoportReduced Pressure Principle Assembly
  • TípusObjektum (egy termék)
  • Megjelenés dátuma2025-09-02
  • Verziószám1
Kapcsolódó adatok
  • Elsődleges anyagNylon
  • Másodlagos anyagRozsdamentes acél
  • Tervezés helyeEgyesült Államok
Besorolások
  • BIMobject kategóriaVízvezeték-szerelés - Szelepek

Termék elérhetősége

Észak-Amerika
Anguilla
Antigua és Barbuda
Aruba
Bahama-szigetek
Barbados
Belize
Bermuda
Brit Virgin-szigetek
Caribbean Netherlands
Costa Rica
Curaçao
Dominikai Közösség
Dominikai Köztársaság
Egyesült Államok
El Salvador
Grenada
Grönland
Guadeloupe
Guatemala
Haiti
Honduras
Jamaica
Kajmán-szigetek
Kanada
Kuba
Martinique
Mexikó
Montserrat
Nicaragua
Panamaváros
Puerto Rico
Saint Kitts és Nevis
Saint Lucia
Saint Pierre és Miquelon
Saint Vincent és a Grenadine-szigetek
Saint-Barthélemy
Saint-Martin
Sint Maarten
Trinidad és Tobago
Turks- és Caicos-szigetek
Virgin-szigetek