CHV-TSTAT-FCU - Heating/Cooling Fan-Coil Thermostat

CHV-TSTAT-FCU - Heating/Cooling Fan-Coil Thermostat

The CHV-TSTAT-FCU is a versatile heating and cooling thermostat for fan coil unit (FCU) HVAC systems. Relative humidity capability can be added through an external remote humidity sensor (sold separately). Although functional as a standalone thermostat, the CHV-TSTAT delivers greatly enhanced functionality as part of a complete home automation system from Crestron®. Available in white, black, or almond, the stylish wall mount design is a complement to any décor.

The large backlit LCD display, navigable using four simple pushbuttons, provides easy access to indoor and outdoor temperature and humidity readings, setpoint adjustments, system mode and fan status indicators, and setup menus. Climate control features include separate heating, cooling, and humidity setpoints with optional automatic changeover between heating and cooling modes. Adjustable anticipators prevent overshooting the set temperature, and continuous fan operation can be selected when needed for increased circulation.

Automation System Integration
Multiple Crestron thermostats may be networked via Cresnet® to any 3-Series® control system, including the DIN-AP3, enabling global temperature and humidity adjustment from any thermostat. Automation functions such as lighting, motorized blinds, or lawn sprinklers can be accessed through two custom remote function pages, and customized text messages can be sent to the LCD display to provide maintenance reminders and other alerts.

Its connection to the control system also allows for full control and scheduling of the CHV-TSTAT-FCU from touch screens and computers throughout the home, and supports extensive flexibility for integration with other devices and systems. In the event that communication with the control system is disrupted for any reason, the CHV-TSTAT-FCU will remain operable to control the HVAC system.

Remote Sensors
Optional remote temperature and humidity sensors can be connected to the CHV-TSTAT-FCU for enhanced flexibility and optimized performance. Climate can be regulated according to an average of multiple sensors, or the built-in sensors can be disabled entirely to allow the CHV-TSTAT-FCU to be installed out of view. Outdoor climate can also be monitored, enabling outdoor low-temperature compensation to prevent condensation on windows during cold weather. The CHV-TSTAT-FCU accepts up to four remote temperature sensors, two remote temp/humidity sensors, or a combination of one temp/humidity sensor and two temperature sensors.

Features
Summary Of Features

Wall-mount thermostat for fan coil unit HVAC systems
Multiple Crestron® thermostats may be networked via Cresnet®
Supports remote humidity sensors and outdoor temperature sensors
Backlit LCD display
Front panel buttons for setup, configuring, and temperature and humidity adjustments[1]
Available in white, black, or almond finishes

Notes:
1. Humidity sensing and outdoor temperature/humidity sensing require additional remote sensors, sold separately. See “Available Accessories” for model names.

Specifikim
  • Measurement Range
     
    Indoor Temperature: 0° to 110°F (-18° to 43°C)
    Outdoor Temperature: -40° to 170°F (-40° to 77°C)[1]
    Humidity: 0% to 100% RH[1]

    Temperature Tolerance
    Over Full Range: ±1°F (±0.5°C)
    At Room Temperatures: ±1°F (+0.1/-0.4°C)

    Setpoint Range
    Auto Setpoint: 38° to 99°F (3° to 37°C)
    Heat only Setpoint: 38° to 89°F (3° to 32°C)
    Cool only Setpoint: 59° to 99°F (15° to 37°C), or 38° to 99°F (3° to 37°C) extended cool mode enabled
    Humidity Setpoint:5% to 70% RH[1]

    Relay Rating
    1 Amp at 40 Volts DC or 24 Volts AC (nominal)

    Power Requirements
    24V: 2 Watts (0.083 Amps) at 24 Volts AC, supplied by heating or cooling system
    Cresnet® Power Usage: ‹1 Watts (‹0.05 Amps at 24 Volts DC), required for Cresnet communication only

    Buttons
    MODE: Accesses user controls - system mode, fan mode, humidifier,[1] Crestron® system, and global update
    VIEW: Accesses humidity reading,[1] outdoor temperature reading,[1] system messages, and remote functions
    UP: Selects user modes and increments selection in setup modes
    DOWN: Selects user modes and decrements selection in setup modes

    Display
    Type: Transflective LCD, backlit
    Size: 2.75 in (6.99 cm)
    Resolution: 128 x 64
    Viewing Angle: ±50° horizontal (at 0° vertical), ±50° vertical (at 0° horizontal)
    Displays current indoor temperature and relative humidity,[1] outdoor temperature and relative humidity,[1] setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages

    Connections
    HVAC:
    (2) 9-position terminal blocks comprising the following:

    Power Connections (Required):
    24 (C): 24V AC common terminal supplies remote 24V AC power to thermostat;
    24 (R): 24V AC reference terminal – Can be connected to R by P4 jumper setting, or tied directly to power source

    HVAC Control Connections (System Dependent):
    HUM, RHU: Humidity Control – Energized together during humidity call;
    R, R: Reference – Used for all system calls (except humidity);
    G-L: Fan Low – Energized to R during call for low-speed fan;
    G-M: Fan – Energized to R during call for medium-speed fan;
    G-H: Fan – Energized to R during call for high-speed fan;
    O: Changeover control – Energized to R during cooling modes;
    B: Energized to R during non-cooling modes;
    W: Heat – Energized to R during call for heating;
    Y: Cool – Energized to R during call for cooling

    Remote Sensing Connections (Optional):
    RSR: Remote Sensor Returns – Common sensor terminal;
    RS1: Remote Sensor terminal – Connect the sensor from RS1 to RSR;
    RS2: Remote Sensor terminal – Connect the sensor from RS2 to RSR
     
    Network
    (1) 4-position terminal block;
    Cresnet slave port, connects to Cresnet control network

    Enclosure
    Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box

    Dimensions
    Height: 3.75 in (96 mm)
    Width: 5.00 in (127 mm)
    Depth: 1.04 in (27 mm)
    Weight: 5.80 oz (165 g)

    Notes:
    1. Humidity sensing and outdoor temperature/humidity sensing require additional remote sensors, sold separately. See “Available Accessories” for model names.

Specifikime teknike
  • Referencë unikecrestron-CHV-TSTAT-FCU
  • Familja e produkteveLighting & Environment
  • Grupi i produkteveClimate Control
  • LlojiObjekt (një objekt të vetëm)
  • Data e botimit2017-12-10
  • Numri i botimit1
  • Gjatësia (inçet)3.75
  • Gjerësia (inçet)5
  • Thellësisë (inçet)1.04
Të ngjashme
  • Materiali kryesorPlastik
  • Projektuar nëMeksikë
  • Prodhuar nëMeksikë
  • Pesha Net (Lbs)0.3625
Klasifikimi
  • Kategoria BIMobjectElektronikë - Pult komandimi
  • IFC classificationElement elektrik
  • CSI MasterFormat 2014 Code40 74 00
  • CSI MasterFormat 2014 TitleTemperature Measurement
  • OmniClass Number23-27 11 11 15 11
  • OmniClass TitleDigital Temperature Controllers

Rajoni i disponueshëm

Europe Asia North America Africa South America Oceania
Andorrë
Afganistan
Anguilë
Afrika e Jugut
Argjentinë
Australi
Austri
Arabia Saudite
Antigua dhe Barbuda
Algjeri
Bolivi
Fixhi
Belgjikë
Armeni
Arubë
Angolë
Brazil
Guam
Bjellorusi
Azerbaixhan
Bahamas
Benin
Ekuador
Ishujt Cook
Bosnjë dhe Hercegovinë
Bahrejn
Barbados
Botsvanë
Guajanë
Ishujt Marshall
Bulgari
Bangladesh
Belizë
Burkina-Faso
Guiana franceze
Ishujt Minor Periferik të Shteteve të Bashkuara
Danimarkë
Brunei
Bermude
Burundi
Ishujt Falkland (Islas Malvinas)
Ishujt Pitcairn
Estoni
Butan
Dominikë
Çad
Kili
Ishujt Solomon
Finlandë
Emiratet e Bashkuara Arabe
Granadë
Côte d’Ivoire
Kolumbi
Ishujt Veriore të Marianës
Francë
Filipinet
Grenlandë
Egjipt
Paraguaj
Ishulli Norfolk
Gërnzi
Gjeorgji
Guadelupë
Eritre
Peru
Kaledonia e Re
Gjermani
Hong-Kong
Guatemalë
Esvatini
Surinami
Kiribati
Gjibraltar
Indi
Haiti
Etiopi
Uruguai
Nauru
Greqi
Indonezi
Honduras
Gabon
Venezuelë
Niue
Holandë
Irak
Ishujt e Virgjër Britanikë
Gambia
Palau
Hungari
Iran
Ishujt e Virgjër të SHBA
Gana
Papua Guinea e Re
Irlandë
Ishujt Cocos (Keeling)
Ishujt Kajman
Guine
Polinezia franceze
Ishujt Alandë
Izrael
Kanadë
Guine-Bisau
Samoa
Ishujt Faroe
Japoni
Karaibe Holandë
Guinea Ekuatoriale
Samoa amerikane
Ishulli i Njeriut
Jemen
Kolektiviteti i Shën Martinit
Kamerun
Shtetet Federale të Mikronezisë
Islandë
Jordani
Kosta Rika
Kenia
Timor-Leste
Itali
Kamboxhi
Kubë
Kepi i Gjelbër
Tokelau
Kroacia
Katar
Kuraçao
Komora
Tonga
Letoni
Kazahstan
Martinikë
Lesoto
Tuvalu
Lihtenshtajn
Kinë
Meksikë
Liberi
Vanuatu
Lituani
Kirgistan
Montserat
Libi
Wallis dhe Futuna
Luksemburg
Korea e jugut
Nikaragua
Madagaskar
Zelanda e Re
Mali i Zi
Korea e Veriut
Panama
Majotë
Maltë
Krishtlindje Island
Porto Riko
Malavi
Maqedonia e Veriut
Kuveit
Republika Domenikane
Mali
Mbretëria e Bashkuar
Laos
Salvador
Marok
Moldovë
Liban
Sen-Bartelemi
Mauritius
Monako
Makao
Shën Kitts dhe Nevis
Mavritani
Norvegji
Malazi
Shën Lucia
Mozambik
Poloni
Maldive
Shën Pierre dhe Miquelon
Namibi
Portugali
Mianmar (Burmë)
Shën Vincent dhe Grenadinet
Niger
Qipro
Mongoli
Shtetet e Bashkuara
Nigeri
Qyteti i Vatikanit
Neoal
Sint-Marten
Republika Demokratike e Kongos
Republika Çeke
Oman
Trinidad dhe Tobago
Republika e Afrikës Qendrore
Rumani
Pakistan
Turks dhe Caicos Islands
Republika e Kongos
Rusi
Palestinë
Xhamaika
Reunion
San-Marino
Singapor
Ruandë
Serbi
Siria
Sahara Perëndimore
Shqipëri
Sri-Lankë
São Tomé dhe Príncipe
Sllovaki
Tajlandë
Sejshelle
Sllovenia
Tajvan
Senegal
Spanjë
Taxhikistan
Shën Helena
Suedi
Territori Britanik i Oqeanit Indian
Sierra-Leone
Svalbard dhe Jan Mayen
Turkmenistan
Somali
Ukrainë
Turqi
Sudan
Xhersej
Uzbekistan
Sudanin Jugor
Zvicër
Vietnam
Tanzani
Togo
Tunizi
Ugandë
Xhibuti
Zambi
Zimbabve