Lead Free* Y Pattern Design Reduced Pressure Zone Assemblies - LF825Y

Ref. unike: LF825Y-Reduced-Pressure-Zone-Assembly
Markë: Febco
Familja e produktit: Backflow Prevention
Grupi i produkteve: Reduced Pressure Zone Assemblies
Data e publikimit: 2019-05-16
Numri i botimeve: 1
Lloj: Objekt (një objekt të vetëm)
Shkarko (1)

Series LF825Y Lead Free* Y pattern design reduced pressure zone assemblies are used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. They are also used in irrigation systems, boiler feed, water lines and other installations requiring maximum protection. They feature a Lead Free* bronze body and threaded ball valve shutoffs. Maximum working pressure: 175psi (12.1 bar).

Features

  • Ultimate mechanical protection of potable water against cross-connection contamination of high hazard (toxic) fluids in water services
  • Modular relief valve for ease of maintenance
  • Used in industrial plants, hospitals, morgues, mortuaries, chemical plants, irrigation systems, boiler feed, water lines, and other installations
  • Meets all specifications of AWWA, ASSE, CSA and approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California

Outlet Connection Size

  • 3/4 IN
  • 1 IN
  • 1 1/4 IN
  • 1 1/2 IN
  • 2 IN

Inlet Connection Size

  • 3/4 IN
  • 1 IN
  • 1 1/4 IN
  • 1 1/2 IN
  • 2 IN


Materiali kryesor: Bronze
Materiali i mesëm:
Projektuar në: United States
Prodhuar në: United States

Kategoritë BIMobject: Pajisje hidraulike - Valvul
IFC klasifikim: Valve
Emri i UNSPSC: Valves
Kodi i UNSPSC: 401416
Uniclass 1.4 Kod: L7136
Uniclass 1.4 Përshkrimi: Valves
Uniclass 2.0 Kod: PR-94-94-xx
Uniclass 2.0 Përshkrimi: Backflow Prevention Devices
Uniclass 2015 Kod: Pr_65_54_95_05
Uniclass 2015 Përshkrimi: Backflow prevention devices
NBS Reference Kod: 94-94-xx
NBS Reference Përshkrimi: Backflow Prevention Devices
CSI MasterFormat 2014 Code: 40 05 67.13
CSI MasterFormat 2014 Title: Reduced-Pressure Zone Backflow Preventers for Process Service
OmniClass Numër: 23-27 31 11
OmniClass Titull: Backflow Preventors
CSI UniFormat II Code: D20
CSI UniFormat II Title: PLUMBING
Ky produkt është në dispozicion në:
North America
  • Canada
  • United States

BIMobject SEEK Properties

Plumbing - Valves

Emri Vlerë
Connection Size 3/4" — 2"
Integral Finish Bronze
Plumbing Fixture Type Reduced Pressure Zone Assembly
Working Pressure 175 psi