High Intensity Infrared Heater, Model M

High Intensity Infrared Heater, Model M

The high-intensity heater Series M has a high-quality stainless steel combustion chamber and modern injector burner, which ensures clean combustion. The M heaters are a cost-effective alternative to our KMI series with a compact and easily mounted reflector hood.

  • 60 years of improving technology from GoGaS featuring their signature bright radiators for increased efficiency
  • Construction of Series M allows for increased flexibility leading to exceeding of expectations in various situations
  • Movable reflectors to allow heat radiators to be used in many applications
    High-quality stainless steel combustion chamber
    Combustion chamber includes modern injection burners which allow combustion to be practically free of hazardous matter and a wide power range from 21, 00 BTU/hr to 125,000 BTU/hr
    Easily mounted reflector with high reflection properties
    Radiation hood not insulated - compact, easy to install, maintenance-friendly
    Controlled preheating mixture to increase the degree of efficiency of the temperature of the gas/air mixture
Specifikim
  • Assemblies shall be CSA approved high-intensity heaters to ANS1 Z83.19 (latest revision) and CSA 2.35 (latest revision). Approval shall include components of the complete heater, including burners, reflectors, accessories, thermostats, and associated controls and specifications. Installations of units shall comply with local building codes, or in their absence, the latest edition of the national regulations and procedures listed below. Heaters shall be electrically grounded in accordance with the National Electric Code, ANSI/NFPA 70 in the US, and the Canadian Electric Code, CSA C22.1 in Canada, and shall comply with all local requirements. Heaters shall be installed only for use with the type of gas appearing on the rating plate, and the installation shall conform to the National Fuel Gas Code, ANSI Z223.1 (NFPA 54) in the US and the Natural Gas and Propane Installation Codes, CAN/CGA B 149.1 & B149.2 in Canada. The Manufacturer warrants to the original owner that the product will be free of defects in material and workmanship. For the M Series, the warranty for all components except for the ceramic burner head assembly is limited to 24 months from the date of installation. The ceramic burner head assembly shall be warranted for an additional 8 years for units that are proven to the satisfaction of the manufacturer to be inoperative due to defects in material or workmanship.

    Basis-of-Design Product shall be Superior Radiant Products Model M Series high-intensity type gas-fired radiant infrared heaters with firing rates as called for within the range of 21 MBH to 125 MBH. CSA approved complete with single body burner head, ignition control, valve & gas pressure switch. Heaters must provide a radiant factor of at least 77.3% as tested to EN 419-2 standard and provide documentation upon request and shall cover the entire infrared spectrum – from short to long wavelengths at a minimum gas inlet pressure of 6.5 inches W.C. (natural gas) and 12 inches W.C. (propane). Maximum inlet pressure for both fuel types is 14 inches W.C. The unit shall draw no more than 20 VA at either 24 VAC or 120VAC, 60Hz. The heater shall perform controlled and clean surface combustion. The resulting quantity of noxious components CO and NOx shall be CO:  20 – 200 ppm; NOx: 4 – 10 ppm. Heater body shall be comprised of Burner-head (mixing chamber, ceramic emitter tiles, and steel mesh), outer body, and reflector assemblies. Burner head shall be stainless steel venturi and shall provide for pre-heat of the air-fuel mixture to achieve higher efficiency. Ignition shall be a solid-state direct spark and make a minimum of 3 ignition attempts before the lockout. Ignition shall have openly accessible sense current contacts. The gas valve shall include a manual valve, two magnetic operators, and a standard gas pressure regulator and have pressure taps to measure inlet and manifold pressures. Controls shall incorporate a gas pressure switch capable of shutting off power to the ignition module in case of inlet gas pressure drops below the minimum requirement.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 77% radiant factor.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).

Specifikime teknike
  • Referencë unikem
  • Familja e produkteveHigh Intensity Heaters
  • Grupi i produkteveMid Efficiency - Series M
  • LlojiObjekt (një objekt të vetëm)
  • Data e botimit2021-02-16
  • Numri i botimit1
Të ngjashme
  • Materiali kryesorAlumin
  • Materiali dytësorQeramike
  • Projektuar nëKanadë
  • Prodhuar nëKanadë
Klasifikimi
  • Kategoria BIMobjectNgrohes, ventilimit dhe ajrit të kondicionuar - Ngrohës
  • IFC classificationNgrohës i hapësirës
  • Emrin UNSPSCSpace heaters
  • UNSPSC code40101819
  • Uniclass 2015 CodePr_70_60_36_70
  • Uniclass 2015 PërshkrimRadiant luminous heaters
  • CSI MasterFormat 2014 Code23 55 23
  • CSI MasterFormat 2014 TitleGas-Fired Radiant Heaters
  • OmniClass Number23-33 15 17 13
  • OmniClass TitleFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II CodeD3090
  • CSI UniFormat II TitleOther HVAC Systems & Equipment

Rajoni i disponueshëm

Europe North America Asia
Andorrë
Anguilë
Armeni
Austri
Antigua dhe Barbuda
Azerbaixhan
Belgjikë
Arubë
Bangladesh
Bjellorusi
Bahamas
Brunei
Bosnjë dhe Hercegovinë
Barbados
Butan
Bulgari
Belizë
Filipinet
Danimarkë
Bermude
Gjeorgji
Estoni
Dominikë
Hong-Kong
Finlandë
Granadë
Indi
Francë
Grenlandë
Indonezi
Gërnzi
Guadelupë
Ishujt Cocos (Keeling)
Gjermani
Guatemalë
Japoni
Gjibraltar
Haiti
Kamboxhi
Greqi
Honduras
Kazahstan
Holandë
Ishujt e Virgjër Britanikë
Kinë
Hungari
Ishujt e Virgjër të SHBA
Kirgistan
Irlandë
Ishujt Kajman
Korea e jugut
Ishujt Alandë
Kanadë
Korea e Veriut
Ishujt Faroe
Karaibe Holandë
Krishtlindje Island
Ishulli i Njeriut
Kolektiviteti i Shën Martinit
Laos
Islandë
Kosta Rika
Makao
Itali
Kubë
Malazi
Kroacia
Kuraçao
Maldive
Letoni
Martinikë
Mianmar (Burmë)
Lihtenshtajn
Meksikë
Mongoli
Lituani
Montserat
Neoal
Luksemburg
Nikaragua
Pakistan
Mali i Zi
Panama
Singapor
Maltë
Porto Riko
Sri-Lankë
Maqedonia e Veriut
Republika Domenikane
Tajlandë
Mbretëria e Bashkuar
Salvador
Tajvan
Moldovë
Sen-Bartelemi
Taxhikistan
Monako
Shën Kitts dhe Nevis
Territori Britanik i Oqeanit Indian
Norvegji
Shën Lucia
Turkmenistan
Poloni
Shën Pierre dhe Miquelon
Uzbekistan
Portugali
Shën Vincent dhe Grenadinet
Vietnam
Qipro
Shtetet e Bashkuara
Qyteti i Vatikanit
Sint-Marten
Republika Çeke
Trinidad dhe Tobago
Rumani
Turks dhe Caicos Islands
Rusi
Xhamaika
San-Marino
Serbi
Shqipëri
Sllovaki
Sllovenia
Spanjë
Suedi
Svalbard dhe Jan Mayen
Ukrainë
Xhersej
Zvicër