Infrared Vacuum System, Model VS

Infrared Vacuum System, Model VS

The Premier Vacuum Series takes full advantage of the performance synergies that only an engineered system can provide. Unlike other “systems” which merely connect multiple unitary style heaters, this maximum design flexibility ensures that all the performance and energy savings requirements of the application can be realized.
Designs are further enhanced by a full complement of additional features, including diverse tubing materials, reflector shielding configurations, multiple vacuum pump sizes, and advanced control options.

  • Custom engineered to precisely fit your building heat requirements.
  • Vacuum vented for maximum safety and operating efficiency.
  • Burner rates from 60,000 to 250,000 BTU/H can fill any heating need.
  • Up to 1.2 million BTUs on a single vacuum pump with single building penetration.
  • Additional fuel economy of at least 5%.
  • Unique, patented burner design results in - precise firing rates, reduced noxious emissions, shorter tailpipe requirements, more burners in series.
  • Reflectors of superior design and performance with side, bottom, and tilted shield options.
  • Run indicator light.
  • Couplings that outperform all others.
  • Burner housing with no loose service doors.
  • Filters are easily changed even with outside combustion air fitted.
  • Vacuum pumps are corrosion resistant, heavy-duty construction with several sizes available to best match the system.
  • Decorative grills can be installed as an option.
  • Warranty - 1 year for the control panel, 3 years for parts, 10 years for burner head. (For more info; please refer to specs and manual).
  • Patented Technology (US Patent #5,842,854).


Specifikim
  • Low-Intensity infrared Premier Vacuum System VS or VS-VH high efficiency condensing or mid-efficiency non-condensing featuring positioned tuned in-line burners to guarantee the best system efficiency in the industry. Firing rates shall be within the range of 20 MBH to 250 MBH (Model VS shall be 80,000 BTU/HR to 250,000 BTU/HR and Model VS-VH Shall be 20,000 BTU/HR to 120,000 BTU/HR). Burners shall be position-tuned and shall be factory designed to operate in a specific in-line position in the radiant branch to ensure equal firing rates for each burner in the branch. Except for the first burner, subsequent burners in a leg shall have firing rates within +/- 2% of each other. Radiant branches shall contain up to 4 burners in-line on a single branch and must be capable of modulating from 60% to 100% of normal firing rates. Minimum end vent flow rates based on design may not exceed the design provided. End vent flow rates of 200% or more will not be permitted. Assemblies shall be CSA approved to the latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a negative pressure burner system where exhaust gases and other products of combustion are routed through the blower.   The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.0 inches W.C. (propane – VS Burners only) and draw no more than 0.2 Amp at 120VAC, 60Hz. Burner head and mounting body shall be cast iron and burner controls shall allow service and diagnostic control checks with the burner operating. Reflector shall have a minimum 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with fewer than 10 surfaces will not be allowed as they allow energy to bounce back to the main heat exchanger tubing. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing and shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall allow fastening of the burner via dual U clamps to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project. 

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Professional Engineer design showing end vent airflow entry rate as equal as or less than design. 
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with an alternate system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model.
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Specifikime teknike
  • Referencë unikevs
  • Familja e produktevePremier Vacuum Series
  • Grupi i produktevePremier VS
  • LlojiObjekt (një objekt të vetëm)
  • Data e botimit2021-02-16
  • Numri i botimit1
Të ngjashme
  • Materiali kryesorÇelik
  • Materiali dytësorAlumin
  • Projektuar nëKanadë
  • Prodhuar nëKanadë
Klasifikimi
  • Kategoria BIMobjectNgrohes, ventilimit dhe ajrit të kondicionuar - Ngrohës
  • IFC classificationNgrohës i hapësirës
  • Emrin UNSPSCSpace heaters
  • UNSPSC code40101819
  • Uniclass 2015 CodePr_70_60_36_72
  • Uniclass 2015 PërshkrimRadiant tube heaters
  • CSI MasterFormat 2014 Code23 55 23
  • CSI MasterFormat 2014 TitleGas-Fired Radiant Heaters
  • OmniClass Number23-33 15 17 13
  • OmniClass TitleFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II CodeD30
  • CSI UniFormat II TitleHVAC

Rajoni i disponueshëm

Europe North America Asia
Andorrë
Anguilë
Armeni
Austri
Antigua dhe Barbuda
Azerbaixhan
Belgjikë
Arubë
Bangladesh
Bjellorusi
Bahamas
Brunei
Bosnjë dhe Hercegovinë
Barbados
Butan
Bulgari
Belizë
Filipinet
Danimarkë
Bermude
Gjeorgji
Estoni
Dominikë
Hong-Kong
Finlandë
Granadë
Indi
Francë
Grenlandë
Indonezi
Gërnzi
Guadelupë
Ishujt Cocos (Keeling)
Gjermani
Guatemalë
Japoni
Gjibraltar
Haiti
Kamboxhi
Greqi
Honduras
Kazahstan
Holandë
Ishujt e Virgjër Britanikë
Kinë
Hungari
Ishujt e Virgjër të SHBA
Kirgistan
Irlandë
Ishujt Kajman
Korea e jugut
Ishujt Alandë
Kanadë
Korea e Veriut
Ishujt Faroe
Karaibe Holandë
Krishtlindje Island
Ishulli i Njeriut
Kolektiviteti i Shën Martinit
Laos
Islandë
Kosta Rika
Makao
Itali
Kubë
Malazi
Kroacia
Kuraçao
Maldive
Letoni
Martinikë
Mianmar (Burmë)
Lihtenshtajn
Meksikë
Mongoli
Lituani
Montserat
Neoal
Luksemburg
Nikaragua
Pakistan
Mali i Zi
Panama
Singapor
Maltë
Porto Riko
Sri-Lankë
Maqedonia e Veriut
Republika Domenikane
Tajlandë
Mbretëria e Bashkuar
Salvador
Tajvan
Moldovë
Sen-Bartelemi
Taxhikistan
Monako
Shën Kitts dhe Nevis
Territori Britanik i Oqeanit Indian
Norvegji
Shën Lucia
Turkmenistan
Poloni
Shën Pierre dhe Miquelon
Uzbekistan
Portugali
Shën Vincent dhe Grenadinet
Vietnam
Qipro
Shtetet e Bashkuara
Qyteti i Vatikanit
Sint-Marten
Republika Çeke
Trinidad dhe Tobago
Rumani
Turks dhe Caicos Islands
Rusi
Xhamaika
San-Marino
Serbi
Shqipëri
Sllovaki
Sllovenia
Spanjë
Suedi
Svalbard dhe Jan Mayen
Ukrainë
Xhersej
Zvicër