Este sitio web utiliza cookies para mejorar y personalizar su experiencia, así como por motivos de análisis, publicidad y otros fines. Haciendo click en el botón “Acepto” está aceptando el uso de cookies (tanto propias como de terceros). Si desea limitar o rechazar el uso de cookies, puede hacerlo en su navegador. También puedes leer más sobre las cookies aplicables y sus preferencias aquí !

Aceptar
;

NV-150-LF-2PS - Nucleus Electronic Mixing Valve

Número de Artículo: nv-150-lf-2ps
Fabricante: Leonard Valve Company
Familia del producto: Mixing Valves for Liquid Services
Grupo del producto: Digitally Controlled Mixing Valves
Fecha de publicación: 2020-11-09
Número de edición: 1
Tipo: Objeto (objeto simple)
Descarga (1)

In support of various states Low Lead laws, Leonard is pleased to offer the new Nucleus line of electronic mixing valves. These valves have all been certified as meeting the lead free requirements. Note: Lead Free is defined as “not more than a weighted average of 0.25 percent when used with respect to the wetted surfaces of pipes and pipe fittings, plumbing fittings, and fixtures”. In addition, these valves are all listed to the stringent performance requirements of the ASSE 1017 Standard.

Leonard’s Nucleus models give plumbing engineers complete system monitoring with outlet temperature control within +/- 2F from set point, regardless of demand. Features include user programmable set point, integral daily sweep and sanitization.

• Digital Mixing Valve with 1 1/4” inlet checkstop valves, 1 ½” Outlet with ball valve and integral RTD Sensor per valve
• Manifold Assembly with 2" inlets, 3" outlet,
• .25 GPM** (0.95 L/min) minimum flow capacity per valve
• Controls water temperature to ± 2°F in accordance with ASSE 1017
• Controls water temperature to ± 2°F at the NV-150-LF during times of low/no system demand
• Maximum operating pressure: 125 PSIG (860KPA)
• Automatic Hot/ Cold Water shutoff upon cold/ hot water inlet supply failure
• User programmable for on-site configuration, high-temperature sanitization mode, and high/ low temperature alarm
• User adjustable settings at the controller or remotely through a Building Automation System/ Building Management System
• Six standard BMS Protocol Languages on-board communication
• Cloud based data logging and monitoring capabilities
• User programmable set point range between 65°F and 180°F
• Displays outlet temperature
• UL Listed 120V plug in power supply with 6’ cord (1 per valve)
• Option for Backup Uninterruptable Power Supply in the event of primary power loss w/ approx. two hours run time
• Factory assembled and tested


Material principal:
Material secundario:
Diseñado en: United States
Fabricado en: United States

Categoría BIMobject: Fontanería - Válvulas
Clasificación IFC: Valve
nombre UNSPSC: Valves
código UNSPSC: 401416
Uniclass 1.4 Código: L71177
Uniclass 1.4 Descripción: Mixing valves
Uniclass 2.0 Código: PR-94
Uniclass 2.0 Descripción: Valves
Uniclass 2015 Código: Pr_65_54_40_16
Uniclass 2015 Descripción: Control valves
NBS Reference Código: 94-94
NBS Reference Descripción: Valves
CSI MasterFormat 2014 Code: 23 09 13.33
CSI MasterFormat 2014 Title: Control Valves
Número OmniClass: 23-27 31 29
Título OmniClass: Mixing Valves
CSI UniFormat II Code: D20
CSI UniFormat II Title: PLUMBING